High-speed Fourier domain Optical Coherence Tomography for structural and functional imaging of the retina
Name
298116698-MIT.pdf
Description
Full printable version
Size
77.69 MB
Format
Adobe PDF
Checksum (MD5)
8429cc6f2ea6f9928930c663dadf14a9
Author(s)
Srinivasan, Vivek Jay
Advisor(s)
James G. Fujimoto.
Alternative Title
High-speed Fourier domain OCT for structural and functional imaging of the retina
Date Issued
2008
Publisher
Massachusetts Institute of Technology
Abstract
Optical Coherence Tomography (OCT) is an emerging optical biomedical imaging technology that enables cross-sectional imaging of scattering tissue with high sensitivity and micron-scale resolution. In conventional OCT, the reference arm path length in a Michelson interferometer is scanned in time to generate a profile of backscattering versus depth from the sample arm. In conventional OCT, a broadband, low coherence light source is used to achieve high axial resolution. However, clinical and research applications of conventional OCT have been limited by low imaging speeds. Recently, new Fourier domain OCT detection methods have enabled speeds of ~20,000-40,000 axial scans per second, which are ~50-100x faster than conventional OCT. These methods are called "Fourier domain" because they detect the interference spectrum and do not require mechanical scanning of the reference arm path length in time. In this thesis, two different technologies for Fourier domain OCT are investigated. The first technology, called spectral OCT, uses a broadband light source and a spectrometer to measure the interference spectrum. The second technology, called swept source OCT, uses a rapidly tunable narrowband laser to measure the interference spectrum over time. Applications of these new technologies for retinal imaging are illustrated, including three-dimensional retinal imaging in animal models, clinical imaging of retinal pathologies, quantification of photoreceptor morphology, and functional imaging of intrinsic stimulus-induced scattering changes in the retina. Finally, using a rapidly tunable laser, ultrahigh-speed swept source OCT imaging at 249,000 axial scans per second, roughly three orders of magnitude faster than conventional OCT, is demonstrated. This technology is applied for three-dimensional snapshots of the retina and optic nerve head and unprecedented visualization of retinal anatomy.
Description
Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2008.
Includes bibliographical references.
Subjects
Electrical Engineering and Computer Science.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Terms of Use
M.I.T. theses are protected by
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
Persistent DSpace Link