Automation of Challenging Spatial-Temporal Biomedical Observations With the Adaptive Scanning Optical Microscope (ASOM)
Name
Potsaid-2009-Automation of Challenging Spatial-Temporal Biomedical Observations With the Adaptive Scanning Optical Microscope (ASOM).pdf
Size
2.17 MB
Format
Adobe PDF
Checksum (MD5)
c15f99fa15431cb54393e02d217f4a3c
Author(s) • •
Potsaid, Benjamin M.
Finger, Fern P.
Wen, John T.
Date Issued
July 2009
Journal
IEEE Transactions on Automation Science and Engineering
Publisher
Institute of Electrical and Electronics Engineers
Citation
Potsaid, B., F.P. Finger, and J.T. Wen. “Automation of Challenging Spatial-Temporal Biomedical Observations With the Adaptive Scanning Optical Microscope (ASOM).” Automation Science and Engineering, IEEE Transactions on 6.3 (2009): 525-535. © Copyright 2009 IEEE
Version
Final published version
Abstract
Biological studies, drug discovery, and medical diagnostics benefit greatly from automated microscope platforms that can outperform even the most skilled human operators in certain tasks. However, the small field-of-view of a traditional microscope operating at high resolution poses a significant challenge in practice. The common approach of using a moving stage suffers from relatively low dynamic bandwidth and agitation to the specimen. This paper describes an automated microscope station based on the novel adaptive scanning optical microscope (ASOM), which combines a high-speed post-objective scanning mirror, a custom design scanner lens, and a microelectromechanical systems (MEMS) deformable mirror to achieve a greatly expanded field-of-view. After describing the layout and operating principle of the ASOM imaging subsystem, we present a system architecture for an automated microscope system suitable for the ASOM's unique wide field and high-speed imaging capabilities. We then describe a low-cost experimental prototype of the ASOM that demonstrates all critical optical characteristics of the instrument, including the calibration of the MEMS deformable mirror. Finally, we present initial biological (living nematode worms) imaging results obtained with the experimental apparatus and discuss the impact of the ASOM on biomedical imaging activities.
MIT Department
Massachusetts Institute of Technology. Research Laboratory of Electronics
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1109/tase.2009.2021358