Economic and design analysis of daylighting a commercial tower in a hot and humid climate
Name
08176126-MIT.pdf
Description
Full printable version
Size
14.23 MB
Format
Adobe PDF
Checksum (MD5)
8b9ce6ea64f74ae093ce64c1b6cb5051
Author(s)
Roscow, Robert F
Advisor(s)
Harvey Bryan.
Date Issued
1981
Publisher
Massachusetts Institute of Technology
Abstract
A forty story commercial office tower in Tampa, Florida was redesigned for daylighting. The methods are outlined and results illustrated, A cooling load comparison is done to determine the economic feasibility of such a strategy. It was found that the smaller cooling plant and greater perimeter office space could offset the increased building expense. Energy savings were also significant, especially for cooling.
Description
Thesis (M. Arch.)--Massachusetts Institute of Technology, Dept. of Architecture, 1981.
MICROFICHE COPY AVAILABLE IN ARCHIVES AND ROTCH.