Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Signal-to-signal neural networks for improved spike estimation from calcium imaging data

Signal-to-signal neural networks for improved spike estimation from calcium imaging data

Thumbnail Image
Download
Name

journal.pcbi.1007921.pdf

Description
Published version
Size

1.81 MB

Format

Unknown

Checksum (MD5)

0f47c0d1fa5877438ba76c40f8bf0f6e

sword-2021-03-18T13:56:08.original.xml (130 B)
Original SWORD entry document
Author(s)
Sebastian, Jilt
•
Sur, Mriganka
•
Murthy, Hema A.
•
Magimai-Doss, Mathew
Date Issued
March 2021
Journal
PLoS Computational Biology
Publisher
Public Library of Science (PLoS)
Version
Final published version
Abstract
Spiking information of individual neurons is essential for functional and behavioral analysis in neuroscience research. Calcium imaging techniques are generally employed to obtain activities of neuronal populations. However, these techniques result in slowly-varying fluorescence signals with low temporal resolution. Estimating the temporal positions of the neuronal action potentials from these signals is a challenging problem. In the literature, several generative model-based and data-driven algorithms have been studied with varied levels of success. This article proposes a neural network-based signal-to-signal conversion approach, where it takes as input raw-fluorescence signal and learns to estimate the spike information in an end-to-end fashion. Theoretically, the proposed approach formulates the spike estimation as a single channel source separation problem with unknown mixing conditions. The source corresponding to the action potentials at a lower resolution is estimated at the output. Experimental studies on the spikefinder challenge dataset show that the proposed signal-to-signal conversion approach significantly outperforms state-of-the-art-methods in terms of Pearson’s correlation coefficient, Spearman’s rank correlation coefficient and yields comparable performance for the area under the receiver operating characteristics measure. We also show that the resulting system: (a) has low complexity with respect to existing supervised approaches and is reproducible; (b) is layer-wise interpretable, and (c) has the capability to generalize across different calcium indicators.
MIT Department
Massachusetts Institute of Technology. Department of Brain and Cognitive Sciences
Terms of Use
Creative Commons Attribution 4.0 International license
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/133651.2
DOI of Published Version
https://doi.org/10.1371/journal.pcbi.1007921
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.