Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter
Name
Khachatryan_2016_J._Inst._11_T10004.pdf
Description
Published version
Size
980.08 KB
Format
Adobe PDF
Checksum (MD5)
cd6c20e768dc47858301733300bdafa3
Author(s) • • •
Apyan, Aram
Bierwagen, Katharina
Brandt, Stephanie Akemi
CMS Collaboration
Date Issued
October 2016
Journal
Journal of Instrumentation
Publisher
IOP Publishing
Citation
Khachatryan, V. et al. "Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter." Journal of Instrumentation 11, 10 (October 2016): T10004 © 2016 CERN 2016 for the benefit of the CMS collaboration
Version
Final published version
Abstract
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.
MIT Department
Massachusetts Institute of Technology. Department of Physics
Massachusetts Institute of Technology. Laboratory for Nuclear Science
Terms of Use
Creative Commons Attribution 3.0 unported license
Persistent DSpace Link
DOI of Published Version