Increasing the Sensitivity of Enzyme-Linked Immunosorbent Assay Using Multiplexed Electrokinetic Concentrator

Thumbnail Image
Download
Name

Han_Increasing the sensitivity.pdf

Size

1.77 MB

Format

Adobe PDF

Checksum (MD5)

94f55fe8d1e1eb9323b1d276cf4e70bb

Author(s)
Cheow, Lih Feng
•
Ko, Sung Hee
•
Kim, Sung Jae
•
Kang, Kwan Hyoung
•
Han, Jongyoon
Alternative Title
Increasing the Sensitivity of ELISA using Multiplexed
Electrokinetic Concentrator
Date Issued
March 2010
Journal
Analytical Chemistry
Publisher
American Chemical Society (ACS)
Citation
Cheow, Lih Feng et al. “Increasing the Sensitivity of Enzyme-Linked Immunosorbent Assay Using Multiplexed Electrokinetic Concentrator.” Analytical Chemistry 82.8 (2010): 3383–3388.
Version
Author's final manuscript
Abstract
We developed a novel method to increase the sensitivity of standard enzyme-linked immunosorbent assay (ELISA) using a multiplexed electrokinetic concentration chip. The poly(dimethylsiloxane) (PDMS) molecular concentrator(1) was used to trap and collect charged fluorescent product of target-bound enzyme turnover reaction of ELISA that occurred in a standard 96 well plate. Detection sensitivities of both prostate specific antigen (PSA) and CA 19-9 (a human pancreatic and gastrointestinal cancer marker) ELISAs in serum are enhanced ~100 fold with a low CV of <17%. We also integrated this method with an on-chip bead-based ELISA that lends itself toward a fully automated on-chip diagnostic device. Detection sensitivity of microfluidic bead-based CA 19-9 ELISA in serum is enhanced ~65 fold compared to the results without the electrokinetic accumulation step. This chip can be directly applied to enhance the readout sensitivity of a wide range of existing ELISA kits at concentrations below the current detection limit.
MIT Department
Massachusetts Institute of Technology. Department of Biological Engineering
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike 3.0
http://creativecommons.org/licenses/by-nc-sa/3.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/73020
DOI of Published Version
https://doi.org/10.1021/ac9024335
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.