Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. On the merits of using multi-stage and counterflow electrodialysis for reduced energy consumption

On the merits of using multi-stage and counterflow electrodialysis for reduced energy consumption

Thumbnail Image
Download
Name

chehayeb_multistage_nohighlight.pdf

Size

1.12 MB

Format

Adobe PDF

Checksum (MD5)

f4aa5a836e18de0e7a18f17e3ef43cda

Download all files submitted through automated deposit
sword-2018-04-30.original.zip (1.03 MB)
Author(s)
Chehayeb, Karim Malek
•
Nayar, Kishor Govind
Date Issued
April 2018
Journal
Desalination
Publisher
Elsevier
Citation
Chehayeb, Karim M. et al. “On the Merits of Using Multi-Stage and Counterflow Electrodialysis for Reduced Energy Consumption.” Desalination 439 (August 2018): 1–16 © 2018 Elsevier B.V.
Version
Author's final manuscript
Abstract
The cost of electrodialysis (ED) systems can be decreased by decreasing their power consumption. Such reductions may be achieved by using degrees of freedom in the system's configuration to obtain a more uniform spatial distribution of the rate of entropy generation, as explained by the theorem of equipartition of entropy generation. In this paper, we study possible improvements to the energy efficiency of electrodialysis through the use of two electric stages with different voltages, and through operation in a counterflow configuration. We first consider how a two-stage ED system should be operated. In particular, we look at how the voltages and current densities should be chosen. In addition, we quantify the effect of operating under two voltages in brackish-water desalination and in high-salinity brine concentration. Finally, we quantify the effect of operating ED in counterflow for the same applications. We show that high ED fixed costs prevent the achievement of significant improvements in energy efficiency. If fixed costs are reduced, and larger systems become cost-effective, we show that a power reduction of up to 29% is possible by going from a single-stage to a two-stage configuration. Keywords: Equipartition of entropy generation; Electrodialysis; Brackish water desalination; Brine concentration; Energy efficiency
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/115368
DOI of Published Version
https://doi.org/10.1016/j.desal.2018.03.026