Parameters that affect the digging of a biologically-inspired underwater borrowing robot
Name
921147696-MIT.pdf
Description
Full printable version
Size
2.36 MB
Format
Adobe PDF
Checksum (MD5)
c20f61fa5a138686436cdac6686013ce
Author(s)
Guitron, Steven Paul
Advisor(s)
Daniel S. Dorsch and Amos G. Winter, V.
Date Issued
2015
Publisher
Massachusetts Institute of Technology
Abstract
RoboClam 2 is a device that burrows based on the movement of the Atlantic razor clam. A functional RoboClam 2 has been built. Testing was conducted in a controlled laboratory environment to determine what parameters of the device and its operation affect its ability to dig both speedily, deeply, and efficiently. Smaller contraction and dilation volume, heavier device weight, and longer contractions above a theoretically calculated minimum fluidizing velocity were all found to correlate with faster digging speed. Future work will involve experimentally determining the minimum fluidizing velocity and the effect of contraction speed on digging ability.
Description
Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.
Cataloged from PDF version of thesis.
Includes bibliographical references (page 29).
Subjects
Mechanical Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Persistent DSpace Link