Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Field validation of the performance of paper-based tests for the detection of the Zika and chikungunya viruses in serum samples

Field validation of the performance of paper-based tests for the detection of the Zika and chikungunya viruses in serum samples

Thumbnail Image
Download
Name

s41551-022-00850-0.pdf

Description
Published version
Size

1.94 MB

Format

Adobe PDF

Checksum (MD5)

0303661c12aef484474d707e4806d46e

sword-2023-01-30T18:58:11.original.xml (130 B)
Original SWORD entry document
Author(s)
Karlikow, Margot
•
da Silva, Severino Jefferson Ribeiro
•
Guo, Yuxiu
•
Cicek, Seray
•
Krokovsky, Larissa
•
Homme, Paige
•
Xiong, Yilin
•
Xu, Talia
•
Calderón-Peláez, Maria-Angelica
•
Camacho-Ortega, Sigrid
more
Date Issued
2022
Journal
Nature Biomedical Engineering
Publisher
Springer Science and Business Media LLC
Citation
Karlikow, Margot, da Silva, Severino Jefferson Ribeiro, Guo, Yuxiu, Cicek, Seray, Krokovsky, Larissa et al. 2022. "Field validation of the performance of paper-based tests for the detection of the Zika and chikungunya viruses in serum samples." Nature Biomedical Engineering, 6 (3).
Version
Final published version
Abstract
AbstractIn low-resource settings, resilience to infectious disease outbreaks can be hindered by limited access to diagnostic tests. Here we report the results of double-blinded studies of the performance of paper-based diagnostic tests for the Zika and chikungunya viruses in a field setting in Latin America. The tests involved a cell-free expression system relying on isothermal amplification and toehold-switch reactions, a purpose-built portable reader and onboard software for computer vision-enabled image analysis. In patients suspected of infection, the accuracies and sensitivities of the tests for the Zika and chikungunya viruses were, respectively, 98.5% (95% confidence interval, 96.2–99.6%, 268 serum samples) and 98.5% (95% confidence interval, 91.7–100%, 65 serum samples) and approximately 2 aM and 5 fM (both concentrations are within clinically relevant ranges). The analytical specificities and sensitivities of the tests for cultured samples of the viruses were equivalent to those of the real-time quantitative PCR. Cell-free synthetic biology tools and companion hardware can provide de-centralized, high-capacity and low-cost diagnostics for use in low-resource settings.
MIT Department
Massachusetts Institute of Technology. Department of Biological Engineering
Terms of Use
Creative Commons Attribution 4.0 International license
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/147789
DOI of Published Version
https://doi.org/10.1038/S41551-022-00850-0
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.