Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Development of an array of Kinetic Inductance Magnetometers (KIMs)

Development of an array of Kinetic Inductance Magnetometers (KIMs)

Thumbnail Image
Download
Name

2102.11001.pdf

Description
Accepted version
Size

3.28 MB

Format

Adobe PDF

Checksum (MD5)

af62bcb9a70e779203a086e7d66e2a70

sword-2022-05-26T14:10:30.original.xml (130 B)
Original SWORD entry document
Author(s)
Sypkens, Sasha
•
Faramarzi, Farzad
•
Colangelo, Marco
•
Sinclair, Adrian
•
Stephenson, Ryan
•
Glasby, Jacob
•
Day, Peter
•
Berggren, Karl
•
Mauskopf, Philip
Date Issued
2021
Journal
IEEE Transactions on Applied Superconductivity
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Citation
Sypkens, Sasha, Faramarzi, Farzad, Colangelo, Marco, Sinclair, Adrian, Stephenson, Ryan et al. 2021. "Development of an array of Kinetic Inductance Magnetometers (KIMs)." IEEE Transactions on Applied Superconductivity, 31 (5).
Version
Author's final manuscript
Abstract
© 2002-2011 IEEE. We describe optimization of a cryogenic magnetometer that uses nonlinear kinetic inductance in superconducting nanowires as the sensitive element instead of a superconducting quantum interference device (SQUID). The circuit design consists of a loop geometry with two nanowires in parallel, serving as the inductive section of a lumped LC resonator similar to a kinetic inductance detector (KID). This device takes advantage of the multiplexing capability of the KID, allowing for a natural frequency multiplexed readout. The Kinetic Inductance Magnetometer (KIM) is biased with a DC magnetic flux through the inductive loop. A perturbing signal will cause a flux change through the loop, and thus a change in the induced current, which alters the kinetic inductance of the nanowires, causing the resonant frequency of the KIM to shift. This technology has applications in astrophysics, material science, and the medical field for readout of Metallic Magnetic Calorimeters (MMCs), axion detection, and magnetoencephalography (MEG).
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Terms of Use
Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International
https://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/142773
DOI of Published Version
https://doi.org/10.1109/TASC.2021.3056322
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.