Time-Resolved Mechanical Spectroscopy of Soft Materials via Optimally Windowed Chirps
Name
PhysRevX.8.041042.pdf
Size
1.28 MB
Format
Adobe PDF
Checksum (MD5)
7a0dba90d1c5c5e5efd64c624d3b9c9d
Author(s) • • • • •
Geri, Michela
Keshavarz, Bavand
Divoux, Thibaut
Clasen, Christian
Curtis, Daniel J.
McKinley, Gareth H.
Date Issued
December 2018
Journal
Physical Review X
Publisher
American Physical Society
Citation
Geri, Michela et al. "Time-Resolved Mechanical Spectroscopy of Soft Materials via Optimally Windowed Chirps." Physical Review X 8, 4 (December 2018): 041042
Version
Final published version
Abstract
The ability to measure the bulk dynamic behavior of soft materials with combined time and frequency resolution is instrumental for improving our fundamental understanding of connections between the microstructural dynamics and the macroscopic mechanical response. Current state-of-the-art techniques are often limited by a compromise between resolution in the time and frequency domains, mainly due to the use of elementary input signals that have not been designed for fast time-evolving systems such as materials undergoing gelation, curing, or self-healing. In this work, we develop an optimized and robust excitation signal for time-resolved mechanical spectroscopy through the introduction of joint frequency- and amplitude-modulated exponential chirps. Inspired by the biosonar signals of bats and dolphins, we optimize the signal profile to maximize the signal-to-noise ratio while minimizing spectral leakage with a carefully designed modulation of the envelope of the chirp, obtained using a cosine-tapered window function. A combined experimental and numerical investigation reveals that there exists an optimal range of window profiles (around 10% of the total signal length) that minimizes the error with respect to standard single-frequency sweep techniques. The minimum error is set by the noise floor of the instrument, suggesting that the accuracy of an optimally windowed-chirp (OWCh) sequence is directly comparable to that achievable with a standard frequency sweep, while the acquisition time can be reduced by up to 2 orders of magnitude, for comparable spectral content. Finally, we demonstrate the ability of this optimized signal to provide time- and frequency-resolved rheometric data by studying the fast gelation process of an acid-induced protein gel using repeated OWCh pulse sequences. The use of optimally windowed chirps enables a robust time-resolved rheological characterization of a wide range of soft materials undergoing rapid mutation and has the potential to become an invaluable rheometric tool for researchers across different disciplines.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1103/PhysRevX.8.041042