  4. EXPERIMENTAL INVESTIGATION OF HIGH EFFICIENCY SINGLE-STAGE MEMBRANE DISTILLATION CONFIGURATIONS

EXPERIMENTAL INVESTIGATION OF HIGH EFFICIENCY SINGLE-STAGE MEMBRANE DISTILLATION CONFIGURATIONS

Thumbnail Image
Download
Name

1-IDAWC_Swaminathan_Experimental Investigation of MD cofigurations.pdf

Size

546.13 KB

Format

Adobe PDF

Checksum (MD5)

1dc532eb79f292a96b4954bf61fddc2e

Author(s)
Swaminathan, Jaichander
•
Chung, Hyung Won
•
Warsinger, David Elan Martin
•
Lienhard, John H.
Date Issued
September 2015
Journal
Proceedings of the 2015 International Desalination Association World Congress on Desalination and Water Reuse
Publisher
International Desalination Association
Citation
Swaminathan, Jaichander, Hyung Won Chung, David M. Warsinger, and John H. Lienhard V. "EXPERIMENTAL INVESTIGATION OF HIGH EFFICIENCY SINGLE-STAGE MEMBRANE DISTILLATION CONFIGURATIONS." 2015 International Desalination Association World Congress on Desalination and Water Reuse (September 2015).
Version
Author's final manuscript
Abstract
A novel single-stage membrane distillation (MD) configuration, known as conductive gap membrane distillation (CGMD), has been suggested by numerical modeling results to achieve up to two times higher energy efficiencies than conventional air gap MD systems. CGMD consists of an MD module with a high thermal conductivity material in the gap region between the membrane and condensing plate, increasing the effective thermal conductivity of the gap. Such systems, if realized practically, could make MD competitive as a large scale thermal desalination technology that is not restricted only to specialized waste heat applications and could also make a stronger case for MD’s use in waste-heat applications. In this study, an experimental comparison of different MD configurations is carried out on a bench scale system keeping membrane area constant, and results are compared to model predictions. The role of energy recovery within the module on improving CGMD efficiency is illustrated. A system with a simple copper woven mesh introduced in the gap in the place of plastic spacers is found to have 40% to 60% higher GOR than AGMD. The potential for further improvements in GOR and issues associated with studying MD efficiency at a laboratory bench scale are also discussed.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/100446
DOI of Published Version
http://s23.a2zinc.net/clients/IDA/IDAWC15/Public/SpeakerDetails.aspx?FromPage=Speakers.aspx&ContactID=263