Reliability analysis of a passive cooling system using a response surface with an application to the Flexible Conversion Ratio Reactor
Name
547426717-MIT.pdf
Description
Full printable version
Size
30.82 MB
Format
Adobe PDF
Checksum (MD5)
4996deef897d4ca3f8342db4b169b722
Author(s)
Fong, Christopher J. (Christopher Joseph)
Advisor(s)
.
Date Issued
2008
Publisher
Massachusetts Institute of Technology
Abstract
A comprehensive risk-informed methodology for passive safety system design and performance assessment is presented and demonstrated on the Flexible Conversion Ratio Reactor (FCRR). First, the methodology provides a framework for risk-informed design decisions and as an example two design options for a decay heat removal system are assessed and quantitatively compared. Next, the reliability of the system is assessed by quantifying the uncertainties related to system performance and propagating these uncertainties through a response surface using Monte Carlo simulation. Finally, a sensitivity study is performed to measure the relative effects of each parameter and to identify ways to maintain, improve, and monitor system performance.
Description
Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Science and Engineering, 2008.
Page 128 blank. Cataloged from PDF version of thesis.
Includes bibliographical references (p. 50-52).
Subjects
Nuclear Science and Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Terms of Use
M.I.T. theses are protected by
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
Persistent DSpace Link