Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s = 7 TeV

Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s = 7 TeV

Thumbnail Image
Download
Name

_2013_J._Inst._8_P09009.pdf

Description
Published version
Size

3.24 MB

Format

Adobe PDF

Checksum (MD5)

c5bd21bc6248d79cd0c845db4216a78e

sword-2019-05-21T12:42:01.original.xml (130 B)
Original SWORD entry document
Author(s)
Apyan, Aram
•
Bauer, Gerry P
•
Busza, Wit
•
Butz, Erik M.
•
Cali, Ivan Amos
•
Chan, M.
•
Dutta, Valentina
•
Gomez-Ceballos, Guillelmo
•
Goncharov, Maxim
•
Kim, Y.
more
Date Issued
September 2013
Journal
Journal of Instrumentation
Publisher
IOP Publishing
Citation
Chatrchyan, S. et al. "Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s = 7 TeV." Journal of Instrumentation 5 (September 2013): P09009 © 2013 CERN for the benefit of the CMS collaboration
Version
Final published version
Abstract
The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of √s = 7 TeV with integrated luminosities of about 5fbinv. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector. The energy resolution for electrons from Z-boson decays is better than 2% in the central region of the ECAL barrel (for pseudorapidity |η| < 0.8) and is 2-5% elsewhere. The derived energy resolution for photons from 125 GeV Higgs boson decays varies across the barrel from 1.1% to 2.6% and from 2.2% to 5% in the endcaps. The calibration of the absolute energy is determined from Ze→+e - decays to a precision of 0.4% in the barrel and 0.8% in the endcaps.
MIT Department
Massachusetts Institute of Technology. Department of Physics
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Massachusetts Institute of Technology. Laboratory for Nuclear Science
Terms of Use
Creative Commons Attribution 3.0 unported license
https://creativecommons.org/licenses/by/3.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/121614
DOI of Published Version
https://doi.org/10.1088/1748-0221/8/09/P09009
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.