Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Nano-beam and nano-target effects in ion radiation

Nano-beam and nano-target effects in ion radiation

Thumbnail Image
Download
Name

proof_corrected_YY_YGL_YY_MPS.pdf

Size

2.83 MB

Format

Adobe PDF

Checksum (MD5)

a8d41cd6424b9c34efeb5055943e5fa2

Author(s)
Berggren, Karl K.
•
Yang, Yang
•
Short, Michael P
•
Kim, Chungsoo
•
Li, Ju
•
Li, Yong Gang
Date Issued
January 2018
Journal
Nanoscale
Publisher
Royal Society of Chemistry
Citation
Yang, Yang, Yong Gang Li, Michael P. Short, Chung-Soo Kim, Karl K. Berggren, and Ju Li. “Nano-Beam and Nano-Target Effects in Ion Radiation.” Nanoscale 10, no. 4 (2018): 1598–1606.
Version
Original manuscript
Abstract
Full three dimensional (3D) simulations of ion implantation are necessary in a wide range of nanoscience and nanotechnology applications to capture the increasing effect of ion leakage out of surfaces. Using a recently developed 3D Monte Carlo simulation code IM3D, we first quantify the relative error of the 1D approach in three applications of nano-scale ion implantation: (1) nano-beam for nitrogen-vacancy (NV) center creation, (2) implantation of nanowires to fabricate p–n junctions, and (3) irradiation of nano-pillars for small-scale mechanical testing of irradiated materials. Because the 1D approach fails to consider the exchange and leakage of ions from boundaries, its relative error increases dramatically as the beam/target size shrinks. Lastly, the “Bragg peak” phenomenon, where the maximum radiation dose occurs at a finite depth away from the surface, relies on the assumption of broad beams. We discovered a topological transition of the point-defect or defect-cluster distribution isosurface when one varies the beam width, in agreement with a previous focused helium ion beam irradiation experiment. We conclude that full 3D simulations are necessary if either the beam or the target size is comparable or below the SRIM longitudinal ion range.
MIT Department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Massachusetts Institute of Technology. Research Laboratory of Electronics
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/120357
DOI of Published Version
https://doi.org/10.1039/c7nr08116b
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.