Assessing the effects of subject motion on T 2 relaxation under spin tagging (TRUST) cerebral oxygenation measurements using volume navigators: Effects of Subject Motion on TRUST
Name
nihms840022.pdf
Description
Accepted version
Size
975.93 KB
Format
Adobe PDF
Checksum (MD5)
ec2d558ec772f1d21ace780798a0a690
Author(s) • • • • • •
Stout, Jeffrey N
Tisdall, M Dylan
McDaniel, Patrick
Gagoski, Borjan
Bolar, Divya S
Grant, Patricia Ellen
Adalsteinsson, Elfar
Date Issued
2017
Journal
Magnetic Resonance in Medicine
Publisher
Wiley
Citation
Stout, J. N., et al. "Assessing the Effects of Subject Motion on T2 Relaxation under Spin Tagging (Trust) Cerebral Oxygenation Measurements Using Volume Navigators." Magn Reson Med (2017).
Version
Author's final manuscript
Abstract
© 2017 International Society for Magnetic Resonance in Medicine Purpose: Subject motion may cause errors in estimates of blood T2 when using the T2-relaxation under spin tagging (TRUST) technique on noncompliant subjects like neonates. By incorporating 3D volume navigators (vNavs) into the TRUST pulse sequence, independent measurements of motion during scanning permit evaluation of these errors. Methods: The effects of integrated vNavs on TRUST-based T2 estimates were evaluated using simulations and in vivo subject data. Two subjects were scanned with the TRUST+vNav sequence during prescribed movements. Mean motion scores were derived from vNavs and TRUST images, along with a metric of exponential fit quality. Regression analysis was performed between T2 estimates and mean motion scores. Also, motion scores were determined from independent neonatal scans. Results: vNavs negligibly affected venous blood T2 estimates and better detected subject motion than fit quality metrics. Regression analysis showed that T2 is biased upward by 4.1 ms per 1 mm of mean motion score. During neonatal scans, mean motion scores of 0.6 to 2.0 mm were detected. Conclusion: Motion during TRUST causes an overestimate of T2, which suggests a cautious approach when comparing TRUST-based cerebral oxygenation measurements of noncompliant subjects. Magn Reson Med 78:2283–2289, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
10.1002/MRM.26616
https://doi.org/10.1002/MRM.26616