Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. Department of Mechanical Engineering
  3. Heat Transfer Laboratory
  4. Heat Transfer Laboratory Technical Reports
  5. Description of boiling project burnout detector

Description of boiling project burnout detector

Thumbnail Image
Download
Name

HTL_TR_1957_011.pdf

Size

3.27 MB

Format

Adobe PDF

Checksum (MD5)

b3f578a522f0cc3e1b0140bcb9e09517

Author(s)
Raymond, M. W.
•
Reynolds John Mitchell
Date Issued
1957
Publisher
Cambridge, Mass. : M.I.T. Heat Transfer Laboratory, [1957]
Series/Report no.
Technical report (Massachusetts Institute of Technology, Heat Transfer Laboratory) ; no. 11.
Abstract
Introduction: In order to effectively utilize the high heat flux available through the mechanism of nucleate boiling in forced convection heat transfer, it is of primary importance that the maximum flux or "burnout" conditions be known for the liquid under consideration. It is a characteristic of the boiling heat transfer process that, as attempts are made to exceed the burnout heat flux, the conditions at the heat transfer surface become such that the heat transfer coefficient decreases with increasing temperature difference between the wall and fluid. If the apparatus in which this process occurs is not of the type in which a constant temperature is imposed, another equilibrium point will be reached at a significantly higher wall temperature. In the case of water at pressures of atmospheric and higher, the wall temperature assumed in the new equilibrium state is high enough to cause failure in all but the most conservatively designed apparatus. Because of the unstable nature of the boiling process beyond the maximum vs. temperature difference on the q/A vs. L T curve, once the burnout temperature difference is exceeded, small power reductions will not save the heat exchanger from the major portion of the incipient temperature jump. Power must be reduced to a relatively low level to insure that excessive temperature will not be developed in the equipment. The time in which this power reduction must be accomplished depends on the particular flux and the heat capacity of the system being used; however, in most practical cases, this time can be expected to be extremely short.
Subjects
Boiling-points.
Detectors.
Persistent DSpace Link
http://hdl.handle.net/1721.1/61487
Repository logo