Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. A Ratiometric Sensor Using Single Chirality Near-Infrared Fluorescent Carbon Nanotubes: Application to In Vivo Monitoring

A Ratiometric Sensor Using Single Chirality Near-Infrared Fluorescent Carbon Nanotubes: Application to In Vivo Monitoring

Thumbnail Image
Download
Name

Giraldo et al_2015_Small.pdf

Size

6.77 MB

Format

Adobe PDF

Checksum (MD5)

e9656a7d0f7fc36ed77156f7f0cb7280

Author(s)
Giraldo, Juan P.
•
Jain, Rishabh M.
•
Wong, Min Hao
•
Iverson, Nicole M.
•
Ben-Naim, Micha
•
Strano, Michael S.
•
Landry, Markita Patricia
•
Kwak, Seonyeong
Date Issued
May 2015
Journal
Small
Publisher
Wiley Blackwell
Citation
Giraldo, Juan P., Markita P. Landry, Seon-Yeong Kwak, Rishabh M. Jain, Min Hao Wong, Nicole M. Iverson, Micha Ben-Naim, and Michael S. Strano. “A Ratiometric Sensor Using Single Chirality Near-Infrared Fluorescent Carbon Nanotubes: Application to In Vivo Monitoring.” Small 11, no. 32 (May 15, 2015): 3973–3984.
Version
Author's final manuscript
Abstract
Advances in the separation and functionalization of single walled carbon nanotubes (SWCNT) by their electronic type have enabled the development of ratiometric fluorescent SWCNT sensors for the first time. Herein, single chirality SWCNT are independently functionalized to recognize either nitric oxide (NO), hydrogen peroxide (H[subscript 2]O[subscript 2]), or no analyte (remaining invariant) to create optical sensor responses from the ratio of distinct emission peaks. This ratiometric approach provides a measure of analyte concentration, invariant to the absolute intensity emitted from the sensors and hence, more stable to external noise and detection geometry. Two distinct ratiometric sensors are demonstrated: one version for H[subscript 2]O[subscript 2], the other for NO, each using 7,6 emission, and each containing an invariant 6,5 emission wavelength. To functionalize these sensors from SWCNT isolated from the gel separation technique, a method for rapid and efficient coating exchange of single chirality sodium dodecyl sulfate-SWCNT is introduced. As a proof of concept, spatial and temporal patterns of the ratio sensor response to H[subscript 2]O[subscript 2] and, separately, NO, are monitored in leaves of living plants in real time. This ratiometric optical sensing platform can enable the detection of trace analytes in complex environments such as strongly scattering media and biological tissues.
MIT Department
Massachusetts Institute of Technology. Department of Chemical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/102316
DOI of Published Version
https://doi.org/10.1002/smll.201403276
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.