Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Thumbnail Image
Download
Name

10052_2022_Article_11072.pdf

Size

2.21 MB

Format

Adobe PDF

Checksum (MD5)

cb33b68c1ee6711df44c1449748e098c

Download all files submitted through automated deposit
art_5304403740460793829.zip (1.68 MB)
Author(s)
Gallina, G.
•
Guan, Y.
•
Retiere, F.
•
Cao, G.
•
Bolotnikov, A.
•
Kotov, I.
•
Rescia, S.
•
Soma, A. K.
•
Tsang, T.
•
Darroch, L.
more
Date Issued
December 13, 2022
Publisher
Springer Berlin Heidelberg
Citation
The European Physical Journal C. 2022 Dec 13;82(12):1125
Version
Final published version
Abstract
Abstract Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0 $$\nu \beta \beta $$ ν β β ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0 $$\nu \beta \beta $$ ν β β of $$^{136}$$ 136 Xe with projected half-life sensitivity of $$1.35\times 10^{28}$$ 1.35 × 10 28  yr. To reach this sensitivity, the design goal for nEXO is $$\le $$ ≤ 1% energy resolution at the decay Q-value ( $$2458.07\pm 0.31$$ 2458.07 ± 0.31  keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.
MIT Department
Massachusetts Institute of Technology. Laboratory for Nuclear Science
Massachusetts Institute of Technology. Department of Physics
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/146905
DOI of Published Version
https://doi.org/10.1140/epjc/s10052-022-11072-8
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.