  4. Cell-free biomimetic polyurethane-based scaffold for breast reconstruction following non-malignant lesion resection. A first-in-human study

Cell-free biomimetic polyurethane-based scaffold for breast reconstruction following non-malignant lesion resection. A first-in-human study

Thumbnail Image
Download
Name

12282_2023_1446_ReferencePDF.pdf

Size

2.04 MB

Format

Adobe PDF

Checksum (MD5)

db21b5dc3aea90a29352190e9be5da49

Download all files submitted through automated deposit
art_2241958778910174417.zip (1.61 MB)
Author(s)
Mariniello, Maria D.
•
Ghilli, Matteo
•
Favati, Benedetta
•
Gerges, Irini
•
Colizzi, Livio
•
Tamplenizza, Margherita
•
Tocchio, Alessandro
•
Martello, Federico
•
Ghilardi, Maria
•
Cossu, Maria C.
more
Date Issued
March 28, 2023
Publisher
Springer Nature Singapore
Citation
Mariniello, Maria D., Ghilli, Matteo, Favati, Benedetta, Gerges, Irini, Colizzi, Livio et al. 2023. "Cell-free biomimetic polyurethane-based scaffold for breast reconstruction following non-malignant lesion resection. A first-in-human study."
Version
Author's final manuscript
Abstract
Abstract Background Based on the volume of tissue removed, conservative surgery (BCS) cannot always guarantee satisfactory cosmetic results, unless resorting to more complex oncoplastic approaches. Investigating an alternative to optimize aesthetic outcomes minimizing surgical complexity, was the purpose of this study. We assessed an innovative surgical procedure based on the use of a biomimetic polyurethane-based scaffold intended for regenerating soft-tissue resembling fat, in patients undergoing BCS for non-malignant breast lesions. Safety and performance of the scaffold, and safety and feasibility of the entire implant procedure were evaluated. Methods A volunteer sample of 15 female patients underwent lumpectomy with immediate device positioning, performing seven study visits with six-month follow-up. We evaluated incidence of adverse events (AEs), changes in breast appearance (using photographs and anthropomorphic measurements), interference with ultrasound and MRI (assessed by two independent investigators), investigator’s satisfaction (through a VAS scale), patient’s pain (through a VAS scale) and quality of life (QoL) (using the BREAST-Q© questionnaire). Data reported are the results of the interim analysis on the first 5 patients. Results No AEs were device related nor serious. Breast appearance was unaltered and the device did not interference with imaging. High investigator’s satisfaction, minimal post-operative pain and positive impact on QoL were also detected. Conclusions Albeit on a limited number of patients, data showed positive outcomes both in terms of safety and performance, paving the way to an innovative breast reconstructive approach with a potential remarkable impact on clinical application of tissue engineering. Trial registration ClinicalTrials.gov (NCT04131972, October 18, 2019).
MIT Department
Massachusetts Institute of Technology. Department of Civil and Environmental Engineering
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
https://hdl.handle.net/1721.1/150934
DOI of Published Version
https://doi.org/10.1007/s12282-023-01446-5
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.