Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Ultraviolet refractometry using field-based light scattering spectroscopy

Ultraviolet refractometry using field-based light scattering spectroscopy

Thumbnail Image
Download
Name

ultraviolet_fu_09.pdf

Size

723.88 KB

Format

Adobe PDF

Checksum (MD5)

e12aa18833a137c21cfafd9da41dd46e

Author(s)
Fu, Dan
•
Choi, Wonshik
•
Sung, Yongjin
•
Oh, Seungeun
•
Yaqoob, Zahid
•
Park, YongKeun
•
Dasari, Ramachandra Rao
•
Feld, Michael S.
Date Issued
October 2009
Journal
Optics Express
Publisher
Optical Society of America
Citation
Dan Fu, Wonshik Choi, Yongjin Sung, Seungeun Oh, Zahid Yaqoob, Yongkeun Park, Ramachandra R. Dasari, and Michael S. Feld, "Ultraviolet refractometry using field-based light scattering spectroscopy," Opt. Express 17, 18878-18886 (2009) http://www.opticsinfobase.org/abstract.cfm?URI=oe-17-21-18878
Version
Author's final manuscript
Abstract
Accurate refractive index measurement in the deep ultraviolet (UV) range is important for the separate quantification of biomolecules such as proteins and DNA in biology. This task is demanding and has not been fully exploited so far. Here we report a new method of measuring refractive index using field-based light scattering spectroscopy, which is applicable to any wavelength range and suitable for both solutions and homogenous objects with well-defined shape such as microspheres. The angular scattering distribution of single microspheres immersed in homogeneous media is measured over the wavelength range 260 to 315 nm using quantitative phase microscopy. By least square fitting the observed scattering distribution with Mie scattering theory, the refractive index of either the sphere or the immersion medium can be determined provided that one is known a priori. Using this method, we have measured the refractive index dispersion of SiO2 spheres and bovine serum albumin (BSA) solutions in the deep UV region. Specific refractive index increments of BSA are also extracted. Typical accuracy of the present refractive index technique is ≤0.003. The precision of refractive index measurements is ≤0.002 and that of specific refractive index increment determination is ≤0.01 mL/g.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Department of Mechanical Engineering
Massachusetts Institute of Technology. Department of Physics
Massachusetts Institute of Technology. Spectroscopy Laboratory
Terms of Use
Attribution-Noncommercial-Share Alike 3.0 Unported
http://creativecommons.org/licenses/by-nc-sa/3.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/52643
DOI of Published Version
http://dx.doi.org/10.1364/OE.17.018878
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.