  4. Gas Transfer in Cellularized Collagen-Membrane Gas Exchange Devices

Gas Transfer in Cellularized Collagen-Membrane Gas Exchange Devices

Thumbnail Image
Download
Name

Lo-2015-Gas Transfer in Cell.pdf

Size

364.03 KB

Format

Adobe PDF

Checksum (MD5)

485077699af38dfda797797b9183d2a5

Author(s)
Lo, Justin H.
•
Bassett, Erik K.
•
Penson, Elliot J. N.
•
Hoganson, David M.
•
Vacanti, Joseph P.
Date Issued
July 2015
Journal
Tissue Engineering Part A
Publisher
Mary Ann Liebert, Inc.
Citation
Lo, Justin H., Erik K. Bassett, Elliot J. N. Penson, David M. Hoganson, and Joseph P. Vacanti. “Gas Transfer in Cellularized Collagen-Membrane Gas Exchange Devices.” Tissue Engineering Part A 21, no. 15–16 (August 2015): 2147–2155. © 2015 Mary Ann Liebert, Inc.
Version
Final published version
Abstract
Chronic lower respiratory disease is highly prevalent in the United States, and there remains a need for alternatives to lung transplant for patients who progress to end-stage lung disease. Portable or implantable gas oxygenators based on microfluidic technologies can address this need, provided they operate both efficiently and biocompatibly. Incorporating biomimetic materials into such devices can help replicate native gas exchange function and additionally support cellular components. In this work, we have developed microfluidic devices that enable blood gas exchange across ultra-thin collagen membranes (as thin as 2 μm). Endothelial, stromal, and parenchymal cells readily adhere to these membranes, and long-term culture with cellular components results in remodeling, reflected by reduced membrane thickness. Functionally, acellular collagen-membrane lung devices can mediate effective gas exchange up to ~288 mL/min/m[superscript 2] of oxygen and ~685 mL/min/m[superscript 2] of carbon dioxide, approaching the gas exchange efficiency noted in the native lung. Testing several configurations of lung devices to explore various physical parameters of the device design, we concluded that thinner membranes and longer gas exchange distances result in improved hemoglobin saturation and increases in pO[subscript 2]. However, in the design space tested, these effects are relatively small compared to the improvement in overall oxygen and carbon dioxide transfer by increasing the blood flow rate. Finally, devices cultured with endothelial and parenchymal cells achieved similar gas exchange rates compared with acellular devices. Biomimetic blood oxygenator design opens the possibility of creating portable or implantable microfluidic devices that achieve efficient gas transfer while also maintaining physiologic conditions.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/98486
DOI of Published Version
https://doi.org/10.1089/ten.TEA.2014.0369
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.