Optimization of vacuum pump device for use in rapid fitment of prosthetic limbs
Name
318911843-MIT.pdf
Description
Full printable version
Size
9.28 MB
Format
Adobe PDF
Checksum (MD5)
28c4667f2ebd625d80ceb0c6d8447b52
Author(s)
Garcia, Philip Thomas
Advisor(s)
Daniel Frey.
Date Issued
2008
Publisher
Massachusetts Institute of Technology
Abstract
Developing World Prosthetics NGO has been in contact with the Jaipur Foot Organization in order to create a human powered vacuum pump for a new technique in prosthetic fitment. The new technique would provide mobility to fitment camps due to the non-reliance of an electrical grid. The design however would need to meet the demands of third-world conditions and heavy, continuous usage. This thesis seeks to explore a variety of mechanisms in order to meet the required specifications of the JFO and the new technique.
Description
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.