Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Correlation chemical shift imaging with low-power adiabatic pulses and constant-density spiral trajectories

Correlation chemical shift imaging with low-power adiabatic pulses and constant-density spiral trajectories

Thumbnail Image
Download
Name

Adalsteinsson_Correlation chemical.pdf

Size

6.22 MB

Format

Adobe PDF

Checksum (MD5)

8fb7bd3048687b5699cb6403e3bd13fb

Author(s)
Andronesi, Ovidiu C.
•
Gagoski, Borjan Aleksandar
•
Adalsteinsson, Elfar
•
Sorensen, A. Gregory
Date Issued
February 2012
Journal
NMR in Biomedicine
Publisher
John Wiley & Sons, Inc
Citation
Andronesi, Ovidiu C., Borjan A. Gagoski, Elfar Adalsteinsson, and A. Gregory Sorensen. “Correlation Chemical Shift Imaging with Low-Power Adiabatic Pulses and Constant-Density Spiral Trajectories.” NMR Biomed. 25, no. 2 (February 2012): 195–209.
Version
Author's final manuscript
Abstract
In this work we introduce the concept of correlation chemical shift imaging (CCSI). Novel CCSI pulse sequences are demonstrated on clinical scanners for two-dimensional Correlation Spectroscopy (COSY) and Total Correlation Spectroscopy (TOCSY) imaging experiments. To date there has been limited progress reported towards a feasible and robust multivoxel 2D COSY. Localized 2D TOCSY imaging is shown for the first time in this work. Excitation with adiabatic GOIA-W(16,4) pulses (Gradient Offset Independent Adiabaticity Wurst modulation) provides minimal chemical shift displacement error, reduced lipid contamination from subcutaneous fat, uniform optimal flip angles, and efficient mixing for coupled spins, while enabling short repetition times due to low power requirements. Constant-density spiral readout trajectories are used to acquire simultaneously two spatial dimensions and f2 frequency dimension in (kx,ky,t2) space in order to speed up data collection, while f1 frequency dimension is encoded by consecutive time increments of t1 in (kx,ky,t1,t2) space. The efficient spiral sampling of the k-space enables the acquisition of a single-slice 2D COSY dataset with an 8 × 8 matrix in 8:32 min on 3 T clinical scanners, which makes it feasible for in vivo studies on human subjects. Here we present the first results obtained on phantoms, human volunteers and patients with brain tumors. The patient data obtained by us represent the first clinical demonstration of a feasible and robust multivoxel 2D COSY. Compared to the 2D J-resolved method, 2D COSY and TOCSY provide increased spectral dispersion which scales up with increasing main magnetic field strength and may have improved ability to unambiguously identify overlapping metabolites. It is expected that the new developments presented in this work will facilitate in vivo application of 2D chemical shift correlation MRS in basic science and clinical studies.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Research Laboratory of Electronics
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/86183
DOI of Published Version
https://doi.org/10.1002/nbm.1730
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.