Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. SuperCDMS Cold Hardware Design

SuperCDMS Cold Hardware Design

Thumbnail Image
Download
Name

10909_2012_Article_584.pdf

Size

594.3 KB

Format

Adobe PDF

Checksum (MD5)

049e6505b42cc6ba9fb91d96533d6909

Download all files submitted through automated deposit
art_7282493075084216053.zip (523.53 KB)
Author(s)
Al Kenany, S.
•
Rolla, Julie A.
•
Godfrey, Gary
•
Brink, Paul L.
•
Seitz, Dennis N.
•
Figueroa-Feliciano, Enectali
•
Huber, Martin E.
•
Hines, Bruce A.
•
Irwin, Kent D.
Date Issued
February 2012
Journal
Journal of Low Temperature Physics
Publisher
Springer US
Citation
Al Kenany, S. et al. “SuperCDMS Cold Hardware Design.” Journal of Low Temperature Physics 167.5–6 (2012): 1167–1172.
Version
Author's final manuscript
Abstract
We discuss the current design of the cold hardware and cold electronics to be used in the upcoming SuperCDMS Soudan deployment. Engineering challenges associated with such concerns as thermal isolation, microphonics, radiopurity, and power dissipation are discussed, along with identifying the design changes necessary for SuperCDMS SNOLAB. The Cryogenic Dark Matter Search (CDMS) employs ultrapure 1-inch thick, 3-inch diameter germanium crystals operating below 50 mK in a dilution cryostat. These detectors give an ionization and phonon signal, which gives us rejection capabilities regarding background events versus dark matter signals.
MIT Department
MIT Kavli Institute for Astrophysics and Space Research
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.