Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Dendrimer-Au nanoparticle network covered alumina membrane for ion rectification and enhanced bioanalysis

Dendrimer-Au nanoparticle network covered alumina membrane for ion rectification and enhanced bioanalysis

Thumbnail Image
Download
Name

acs.nanolett.9b05066.pdf

Description
Published version
Size

4.5 MB

Format

Adobe PDF

Checksum (MD5)

63578d382bad14a02ba20789a8cab508

sword-2020-04-06T14:55:43.original.xml (130 B)
Original SWORD entry document
Author(s)
Wang, Chen
•
Zhao, Xiao-Ping
•
Liu, Fei-Fei
•
Chen, Yuming
•
Xia, Xing-Hua
•
Li, Ju
Date Issued
February 2020
Journal
Nano letters
Publisher
American Chemical Society (ACS)
Citation
Wang, Chen, et al., "Dendrimer-Au nanoparticle network covered alumina membrane for ion rectification and enhanced bioanalysis." Nano letters 20, 3 (2020): p. 1846-54 doi 10.1021/acs.nanolett.9b05066 ©2020 Author(s)
Version
Final published version
Abstract
Ion transport in an artificial asymmetric nanoporous membrane, which is similar to biological ion channels, can be used for biosensing. Here, a dendrimer-Au nanoparticle network (DAN) is in situ assembled on a nanoporous anodic aluminum oxide (AAO) surface, forming a DAN/AAO hybrid membrane. Benefiting from the high surface area and anion selectivity of DAN, the prepared DAN/AAO hybrid presents selective ion transport. Under a bias potential, a diode-like current-potential (I-V) response is observed. The obtained ionic current rectification (ICR) property can be tuned by the ion valence and pH value of the electrolyte. The rectified ionic current endows the as-prepared DAN/AAO hybrid with the ability of enhanced bioanalysis. Sensitive capture and detection of circulating tumor cells (CTCs) with a detection limit of 80 cells mL-1 as well as excellent reusability can be achieved. ©2020 keywords: dendrimer-Au nanoparticle network; hybrid membrane; ion selectivity; ionic current rectification; enhanced bioanalysis
MIT Department
Massachusetts Institute of Technology. Department of Materials Science and Engineering
Terms of Use
Creative Commons Attribution 4.0 International license
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/124494
DOI of Published Version
https://doi.org/10.1021/acs.nanolett.9b05066
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.