Analysis of harmonic distortion in an Integrated Power System for naval applications
Name
63789689-MIT.pdf
Description
Full printable version
Size
11.51 MB
Format
Adobe PDF
Checksum (MD5)
b9edebeb3dc75fb241a4f5f633e1ff8b
Author(s)
West, Edward G., S.M. Massachusetts Institute of Technology
Advisor(s)
Timothy J. McCoy.
Date Issued
2005
Publisher
Massachusetts Institute of Technology
Abstract
This research quantifies the voltage distortion over the broad range of operating conditions experienced by a Naval warship. A steady state model of an Integrated Power System (IPS) was developed in a commercially available power system simulation tool. The system chosen for this study was a three-phase, 4160 VAC, 80 MW power system with a 450 VAC bus to supply traditional ship service loads. Sensitive loads, such as combat systems equipment, are isolated from the harmonic content of the 450 volt bus via solid state inverters. Power generation for this system included two 30 MW and two 10 MW generators. The sizing of these generators was based on operating configurations that would result in the best fuel efficiency under the most common loading conditions. Model components were simulated and compared to data recorded for the U.S. Navy's Full Scale Advanced Development (FSAD) test system for the IPS at the Philadelphia Land Based Engineering Site (LBES). The propulsion motor used in the simulations was developed based on the advanced induction motor installed at LBES.
(cont.) Various loading conditions, including battle, cruise and anchor were simulated for both 10⁰F and 90⁰F ambient design conditions and with propulsion loads ranging from 0% to 100%. Numerous system configuration changes were implemented to determine their impact on system harmonics. These included operating the propulsion converter front end rectifiers in both controlled (varying commutation angle) and uncontrolled (diode bridge) configurations; implementation of both twelve and six pulse rectification; and installation of a tuned passive 5th harmonic filter. The simulation results are compared to both IEEE Std 519-1992 and Mil-Std 1399.
Description
Thesis (Nav. E.)--Massachusetts Institute of Technology, Dept. of Ocean Engineering; and, (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2005.
Includes bibliographical references (p. 89-91).
Subjects
Ocean Engineering.
Electrical Engineering and Computer Science.
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Department of Ocean Engineering
Terms of Use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Persistent DSpace Link