Evaluating energy dissipation during expansion in a refrigeration cycle using flue pipe acoustic resonators

Thumbnail Image
Download
Name

314420576-MIT.pdf

Description
Full printable version
Size

3.14 MB

Format

Adobe PDF

Checksum (MD5)

7f07c253b00d7e32ca7cb67155fcdf07

Author(s)
Luckyanova, Maria N. (Maria Nickolayevna)
Advisor(s)
John G. Brisson.
Date Issued
2008
Publisher
Massachusetts Institute of Technology
Abstract
This research evaluates the feasibility of using a flue pipe acoustic resonator to dissipate energy from a refrigerant stream in order to achieve greater cooling power from a cryorefrigeration cycle. Two models of the acoustic operation of flue pipe resonant systems are examined: an electrical circuit analog that represents the linear approximation of the acoustic system and a numerical model based on empirical data. The electrical analog yields a symbolic representation for the power that can potentially be dissipated from the acoustic stream. Ongoing research into these acoustic systems, however, shows that the electrical analog, which neglects nonlinear effects, is incomplete and overestimates the operation of a pipe. However, the analogy can be used to quickly find the order of magnitude of power dissipated from the acoustic resonator. A subsequent data-based model allows for a more accurate quantitative estimation of the potential efficiency of the flue pipe in extracting work and thereby dissipating energy from a refrigerant stream. The efficiency of extracting work from a refrigerant stream using the acoustic system analyzed here ranges from 10% to 60%. The range is so large because the quality factor of the experimental flue pipe is unknown. This quality factor is imperative in determining the power dissipation. Further research should optimize the quality factor. A large quality factor causes less amplitude attenuation than a small one, but a smaller one dissipates more of the stored energy. The results of the models are compared to the efficiencies of existing technology, specifically the recently invented thermo acoustic expansion valve (TEV). It is found that the efficiency of the TEV is less than the theoretical results deduced from the numerical model. At an efficiency of approximately 10%, the technology represents a gain in cooling power, but further optimization using the results of this research can increase this gain even more.
Description
Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.
"June 2008."
Includes bibliographical references (p. 27-29).
Subjects
Mechanical Engineering.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
M.I.T. theses are protected by
copyright. They may be viewed from this source for any purpose, but
reproduction or distribution in any format is prohibited without written
permission. See provided URL for inquiries about permission.
http://dspace.mit.edu/handle/1721.1/7582
Persistent DSpace Link
http://hdl.handle.net/1721.1/45328
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.