Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Fast and Fourier: extreme mass ratio inspiral waveforms in the frequency domain

Fast and Fourier: extreme mass ratio inspiral waveforms in the frequency domain

Thumbnail Image
Download
Name

fams-09-1266739.pdf

Description
Published version
Size

2.15 MB

Format

Adobe PDF

Checksum (MD5)

c4d110ef1dd7f2c9b14ca49cea5d98ee

sword-2026-04-02T14:46:29.original.xml (130 B)
Original SWORD entry document
Author(s)
Speri, Lorenzo
•
Katz, Michael L
•
Chua, Alvin JK
•
Hughes, Scott A
•
Warburton, Niels
•
Thompson, Jonathan E
•
Chapman-Bird, Christian EA
•
Gair, Jonathan R
Date Issued
January 12, 2024
Journal
Frontiers in Applied Mathematics and Statistics
Publisher
Frontiers Media SA
Citation
Speri L, Katz ML, Chua AJK, Hughes SA, Warburton N, Thompson JE, Chapman-Bird CEA and Gair JR (2024) Fast and Fourier: extreme mass ratio inspiral waveforms in the frequency domain. Front. Appl. Math. Stat. 9:1266739.
Version
Final published version
Abstract
Extreme Mass Ratio Inspirals (EMRIs) are one of the key sources for future spacebased gravitational wave interferometers. Measurements of EMRI gravitational waves are expected to determine the characteristics of their sources with subpercent precision. However, their waveform generation is challenging due to the long duration of the signal and the high harmonic content. Here, we present the first ready-to-use Schwarzschild eccentric EMRI waveform implementation in the frequency domain for use with either graphics processing units (GPUs) or central processing units (CPUs). We present the overall waveform implementation and test the accuracy and performance of the frequency domain waveforms against the time domain implementation. On GPUs, the frequency domain waveform takes in median 0.044 s to generate and is twice as fast to compute as its time domain counterpart when considering massive black hole masses ≥ 2 × 106 M⊙ and initial eccentricities e0 > 0.2. On CPUs, the median waveform evaluation time is 5 s, and it is five times faster in the frequency domain than in the time domain. Using a sparser frequency array can further speed up the waveform generation, reaching up to 0.3 s. This enables us to perform, for the first time, EMRI parameter inference with fully relativistic waveforms on CPUs. Future EMRI models, which encompass wider source characteristics (particularly black hole spin and generic orbit geometries), will require significantly more harmonics. Frequency domain models will be essential analysis tools for these astrophysically realistic and important signals.
MIT Department
Massachusetts Institute of Technology. Department of Physics
MIT Kavli Institute for Astrophysics and Space Research
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/165307
DOI of Published Version
https://doi.org/10.3389/fams.2023.1266739
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.