Comparison of cardiovascular parameter estimation methods using swine data
Name
10877_2019_322_ReferencePDF.pdf
Size
1.55 MB
Format
Adobe PDF
Checksum (MD5)
86f83c4d01983f6bab4f8860bf14e2ab
Author(s) • •
Arai, Tatsuya
Lee, Kichang
Cohen, Richard J.
Date Issued
May 2019
Journal
Journal of Clinical Monitoring and Computing
Publisher
Springer Netherlands
Citation
Arai, Tatsuya et al., "Comparison of cardiovascular parameter estimation methods using swine data." Journal of Clinical Monitoring and Computing 34, 2 (April 2020): 261–70 ©2019 Authors
Version
Author's final manuscript
Abstract
Abstract: In this study, new and existing methods of estimating stroke volume, cardiac output and total peripheral resistance from analysis of the arterial blood pressure waveform were tested over a wide range of conditions. These pulse contour analysis methods (PCMs) were applied to data obtained in six swine during infusion of volume, phenylephrine, dobutamine, isoproterenol, esmolol and nitroglycerine as well as during progressive hemorrhage. Performance of PCMs was compared using true end-ejection pressures as well as estimated end-ejection pressures. There was considerable overlap in the accuracies of the PCMs when using true end-ejection measures. However, for perhaps the most clinically relevant condition, where radial artery pressure is the input, only Wesseling’s Corrected Impedance method and the Kouchoukos Correction method achieved statistically superior results. We introduced a method of estimating end-ejection by determining when the systolic pressure dropped to a value equal to the sum of the end-diastolic pressure plus a fraction of the pulse pressure. The most accurate estimation of end-ejection was obtained when that fraction was set to 60% for the central arterial pressure and to 50% for the femoral and radial arterial pressures. When the estimated end-ejection measures were used for the PCMs that depend on end-ejection measures and when radial artery pressure was used as the input, only Wesseling’s Corrected Impedance method and the modified Herd’s method achieved statistically superior results. This study provides a systematic comparison of multiple PCMs’ ability to estimate stroke volume, cardiac output, and total peripheral resistance and introduces a new method of estimating end-systole.
MIT Department
Massachusetts Institute of Technology. Department of Aeronautics and Astronautics
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1007/s10877-019-00322-y