Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology
Name
nihms848185.pdf
Size
642.49 KB
Format
Adobe PDF
Checksum (MD5)
e23066f16a2a1449ed42fca556a4a684
Author(s) •
Connizzo, Brianne K
Grodzinsky, Alan J
Date Issued
January 2017
Journal
Journal of Biomechanics
Publisher
Elsevier BV
Citation
Connizzo, Brianne K., and Alan J. Grodzinsky. “Tendon Exhibits Complex Poroelastic Behavior at the Nanoscale as Revealed by High-Frequency AFM-Based Rheology.” Journal of Biomechanics 54 (March 2017): 11–18 © 2017 Elsevier Ltd
Version
Author's final manuscript
Abstract
Tendons transmit load from muscle to bone by utilizing their unique static and viscoelastic tensile properties. These properties are highly dependent on the composition and structure of the tissue matrix, including the collagen I hierarchy, proteoglycans, and water. While the role of matrix constituents in the tensile response has been studied, their role in compression, particularly in matrix pressurization via regulation of fluid flow, is not well understood. Injured or diseased tendons and tendon regions that naturally experience compression are known to have alterations in glycosaminoglycan content, which could modulate fluid flow and ultimately mechanical function. While recent theoretical studies have predicted tendon mechanics using poroelastic theory, no experimental data have directly demonstrated such behavior. In this study, we use high-bandwidth AFM-based rheology to determine the dynamic response of tendons to compressive loading at the nanoscale and to determine the presence of poroelastic behavior. Tendons are found to have significant characteristic dynamic relaxation behavior occurring at both low and high frequencies. Classic poroelastic behavior is observed, although we hypothesize that the full dynamic response is caused by a combination of flow-dependent poroelasticity as well as flow-independent viscoelasticity. Tendons also demonstrate regional dependence in their dynamic response, particularly near the junction of tendon and bone, suggesting that the structural and compositional heterogeneity in tendon may be responsible for regional poroelastic behavior. Overall, these experiments provide the foundation for understanding fluid-flow-dependent poroelastic mechanics of tendon, and the methodology is valuable for assessing changes in tendon matrix compressive behavior at the nanoscale. Keywords: Poroelasticity; Viscoelasticity; Tendon; AFM; Nanomechanics
MIT Department
Massachusetts Institute of Technology. Center for Biomedical Engineering
Massachusetts Institute of Technology. Department of Biological Engineering
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-NonCommercial-NoDerivs License
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1016/J.JBIOMECH.2017.01.029