Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Large-Scale Magnetic Microcalorimeter Arrays for the Lynx X-Ray Microcalorimeter

Large-Scale Magnetic Microcalorimeter Arrays for the Lynx X-Ray Microcalorimeter

Thumbnail Image
Download
Name

10909_2022_2767_ReferencePDF.pdf

Size

833.33 KB

Format

Adobe PDF

Checksum (MD5)

e59d5e931799e1015bcc3f3a71455f53

Download all files submitted through automated deposit
art_6666722453386494638.zip (794.27 KB)
Author(s)
Devasia, Archana M.
•
Bandler, Simon R.
•
Ryu, Kevin
•
Stevenson, Thomas R.
•
Yoon, Wonsik
Date Issued
July 6, 2022
Publisher
Springer US
Citation
Devasia, Archana M., Bandler, Simon R., Ryu, Kevin, Stevenson, Thomas R. and Yoon, Wonsik. 2022. "Large-Scale Magnetic Microcalorimeter Arrays for the Lynx X-Ray Microcalorimeter."
Version
Author's final manuscript
Abstract
Abstract The Lynx X-ray microcalorimeter (LXM) is an imaging spectrometer consisting of an array of greater than 100,000 pixels. Magnetic microcalorimeter (MMC) technology is a leading contender for detectors for the LXM. In this work, we detail the design of a full-size LXM MMC array fabricated using superconducting, multi-layer, buried wiring, with all pixels wired out on a full-size support wafer. We adopt a scheme that facilitates mixing and matching deep UV (DUV) and i-line (365 nm) steppers to stitch the high feature resolution detector array to the large field fanout wiring. To realize the main array of the microcalorimeter, we also employ a sandwich geometry. In this type of pixel, a superconducting ground plane placed above a paramagnetic sensor forces most of the magnetic flux to remain inside the sensor. This device aims to improve the coupling of the sensor to the pick-up coil, and thus enhance the energy resolution. Additionally, we introduce the integration of superconducting flux transformers to optimize the performance of the Ultra High Resolution Array. The wiring to each pixel terminates on bump bond pads, which allow future 2D microwave SQUID-based multiplexer chips to be indium bump bonded over the buried wiring. We present fabrication results and preliminary room temperature electrical measurements.
MIT Department
Lincoln Laboratory
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
https://hdl.handle.net/1721.1/146613
DOI of Published Version
https://doi.org/10.1007/s10909-022-02767-z