Optimized Computer-Aided Segmentation and Three-Dimensional Reconstruction Using Intracoronary Optical Coherence Tomography
Name
ieee_acc_final.pdf
Size
1.4 MB
Format
Adobe PDF
Checksum (MD5)
4a788241c99533fb38569075b734cb55
Author(s) • • • • • • •
Athanasiou, Lambros
Nezami, Farhad Rikhtegar
Galon, Micheli Zanotti
Lopes, Augusto Celso
Lemos, Pedro Alves
De La Torre Hernandez, Jose Maria
Ben Assa, Eyal Benjamin
Edelman, Elazer R
Date Issued
August 13, 2018
Journal
IEEE Journal of Biomedical and Health Informatics
Publisher
Institute of Electrical and Electronics Engineers (IEEE)
Citation
Athanasiou, Lambros et al. “Optimized Computer-Aided Segmentation and Three-Dimensional Reconstruction Using Intracoronary Optical Coherence Tomography.” IEEE Journal of Biomedical and Health Informatics 22, 4 (July 2018): 1168–1176 © 2013 IEEE
Version
Author's final manuscript
Abstract
We present a novel and time-efficient method for intracoronary lumen detection, which produces three-dimensional (3-D) coronary arteries using optical coherence tomographic (OCT) images. OCT images are acquired for multiple patients and longitudinal cross-section (LOCS) images are reconstructed using different acquisition angles. The lumen contours for each LOCS image are extracted and translated to 2-D cross-sectional images. Using two angiographic projections, the centerline of the coronary vessel is reconstructed in 3-D, and the detected 2-D contours are transformed to 3-D and placed perpendicular to the centerline. To validate the proposed method, 613 manual annotations from medical experts were used as gold standard. The 2-D detected contours were compared with the annotated contours, and the 3-D reconstructed models produced using the detected contours were compared to the models produced by the annotated contours. Wall shear stress (WSS), as dominant hemodynamics factor, was calculated using computational fluid dynamics and 844 consecutive 2-mm segments of the 3-D models were extracted and compared with each other. High Pearson's correlation coefficients were obtained for the lumen area (r = 0.98) and local WSS (r = 0.97) measurements, while no significant bias with good limits of agreement was shown in the Bland-Altman analysis. The overlapping and nonoverlapping areas ratio between experts' annotations and presented method was 0.92 and 0.14, respectively. The proposed computer-aided lumen extraction and 3-D vessel reconstruction method is fast, accurate, and likely to assist in a number of research and clinical applications.
MIT Department
Institute for Medical Engineering and Science
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1109/JBHI.2017.2762520