Resonant dampers for parametric instabilities in gravitational wave detectors
Name
PhysRevD.92.082001.pdf
Size
1.01 MB
Format
Adobe PDF
Checksum (MD5)
2f71bd651ef9ada2633219d6da092d80
Author(s) • • •
Barsotti, Lisa
Gras, Slawomir
Fritschel, Peter K
Evans, Matthew J
Date Issued
October 2015
Journal
Physical Review D
Publisher
American Physical Society
Citation
Gras, S., P. Fritschel, L. Barsotti, and M. Evans. “Resonant Dampers for Parametric Instabilities in Gravitational Wave Detectors.” Phys. Rev. D 92, no. 8 (October 2015). © 2015 American Physical Society
Version
Final published version
Abstract
Advanced gravitational wave interferometric detectors will operate at their design sensitivity with nearly ~1 MW of laser power stored in the arm cavities. Such large power may lead to the uncontrolled growth of acoustic modes in the test masses due to the transfer of optical energy to the mechanical modes of the arm cavity mirrors. These parametric instabilities have the potential to significantly compromise the detector performance and control. Here we present the design of “acoustic mode dampers” that use the piezoelectric effect to reduce the coupling of optical to mechanical energy. Experimental measurements carried on an Advanced LIGO-like test mass have shown a tenfold reduction in the amplitude of several mechanical modes, thus suggesting that this technique can greatly mitigate the impact of parametric instabilities in advanced detectors.
MIT Department
Massachusetts Institute of Technology. Department of Physics
MIT Kavli Institute for Astrophysics and Space Research
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1103/PhysRevD.92.082001