An Ultra-Low-Power Pulse Oximeter Implemented With an Energy-Efficient Transimpedance Amplifier
Name
Tavakoli-2010-An Ultra-Low-Power Pulse Oximeter Implemented With an Energy-Efficient Transimpedance Amplifier.pdf
Size
1.1 MB
Format
Adobe PDF
Checksum (MD5)
8a9cf419ef8249d0e1a6d72859994445
Author(s) • •
Tavakoli, Maziar
Turicchia, Lorenzo
Sarpeshkar, Rahul
Date Issued
December 2009
Journal
IEEE transactions on biomedical circuits and systems
Publisher
Institute of Electrical and Electronics Engineers
Citation
Tavakoli, M., L. Turicchia, and R. Sarpeshkar. “An Ultra-Low-Power Pulse Oximeter Implemented With an Energy-Efficient Transimpedance Amplifier.” Biomedical Circuits and Systems, IEEE Transactions On 4.1 (2010) : 27-38. Copyright © 2010, IEEE
Version
Final published version
Abstract
Pulse oximeters are ubiquitous in modern medicine to noninvasively measure the percentage of oxygenated hemoglobin in a patient's blood by comparing the transmission characteristics of red and infrared light-emitting diode light through the patient's finger with a photoreceptor. We present an analog single-chip pulse oximeter with 4.8-mW total power dissipation, which is an order of magnitude below our measurements on commercial implementations. The majority of this power reduction is due to the use of a novel logarithmic transimpedance amplifier with inherent contrast sensitivity, distributed amplification, unilateralization, and automatic loop gain control. The transimpedance amplifier, together with a photodiode current source, form a high-performance photoreceptor with characteristics similar to those found in nature, which allows LED power to be reduced. Therefore, our oximeter is well suited for portable medical applications, such as continuous home-care monitoring for elderly or chronic patients, emergency patient transport, remote soldier monitoring, and wireless medical sensing. Furthermore, our design obviates the need for an A-to-D and digital signal processor and leads to a small single-chip solution. We outline how extensions of our work could lead to submilliwatt oximeters.
Subjects
United States. Office of Naval Research (Contract No. N00014-02-1- 0434)
MIT Department
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Massachusetts Institute of Technology. Research Laboratory of Electronics
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1109/tbcas.2009.2033035