Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Oxygen Surface Exchange Kinetics Measurement by Simultaneous Optical Transmission Relaxation and Impedance Spectroscopy: Sr(Ti,Fe)O[subscript 3-x] Thin Film Case Study

Oxygen Surface Exchange Kinetics Measurement by Simultaneous Optical Transmission Relaxation and Impedance Spectroscopy: Sr(Ti,Fe)O[subscript 3-x] Thin Film Case Study

Thumbnail Image
Download
Name

Oxygen surface exchange kinetics measurement by simultaneous optical transmission relaxation and impedance spectroscopy Sr Ti Fe O3 x thin film case.pdf

Size

1.28 MB

Format

Adobe PDF

Checksum (MD5)

edb3ebe7e19ccbfcd9e8ba49910916a6

Download all files submitted through automated deposit
sword-2018-09-28.original.zip (1.12 MB)
Author(s)
Perry, Nicola
•
Kim, Jae Jin
•
Tuller, Harry L
Date Issued
February 2018
Journal
Science and Technology of Advanced Materials
Publisher
IOP Publishing
Citation
Perry, Nicola H. et al “Oxygen Surface Exchange Kinetics Measurement by Simultaneous Optical Transmission Relaxation and Impedance Spectroscopy: Sr(Ti,Fe)O[subscript 3-x] Thin Film Case Study.” Science and Technology of Advanced Materials 19, 1 (February 2018): 130–141 © 2018 The Author(s)
Version
Final published version
Abstract
We compare approaches to measure oxygen surface exchange kinetics, by simultaneous optical transmission relaxation (OTR) and AC-impedance spectroscopy (AC-IS), on the same mixed conducting SrTi[subscript 0.65]Fe[subscript 0.35]O[subscript 3-x] film. Surface exchange coefficients were evaluated as a function of oxygen activity in the film, controlled by gas partial pressure and/or DC bias applied across the ionically conducting yttria-stabilized zirconia substrate. Changes in measured light transmission through the film over time (relaxations) resulted from optical absorption changes in the film corresponding to changes in its oxygen and oxidized Fe (~Fe[superscript 4+]) concentrations; such relaxation profiles were successfully described by the equation for surface exchange-limited kinetics appropriate for the film geometry. The k[subscript chem] values obtained by OTR were significantly lower than the AC-IS derived k[subscript chem] values and k[subscript q] values multiplied by the thermodynamic factor (bulk or thin film), suggesting a possible enhancement in k by the metal current collectors (Pt, Au). Long-term degradation in kchemand kqvalues obtained by AC-IS was also attributed to deterioration of the porous Pt current collector, while no significant degradation was observed in the optically derived kchemvalues. The results suggest that, while the current collector might influence measurements by AC-IS, the OTR method offers a continuous, in situ, and contact-free method to measure oxygen exchange kinetics at the native surfaces of thin films. Keywords: Thin films; perovskite; mixed ionic and electronic conductor; oxygen surface exchange; optical absorption; impedance spectroscopy
MIT Department
Massachusetts Institute of Technology. Department of Materials Science and Engineering
Terms of Use
Creative Commons Attribution 4.0 International License
http://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/118587
DOI of Published Version
https://doi.org/10.1080/14686996.2018.1430448
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.