MRI of the human brain at 130 microtesla
Name
Inglis-2013-MRI of the human bra.pdf
Size
1.19 MB
Format
Adobe PDF
Checksum (MD5)
448c7a60049a982db9cd13d5e86a554f
Author(s) • • • • •
Inglis, Ben
Buckenmaier, Kai
SanGiorgio, Paul
Pedersen, Anders F.
Nichols, Matthew Alan
Clarke, John
Date Issued
November 2013
Journal
Proceedings of the National Academy of Sciences
Publisher
National Academy of Sciences (U.S.)
Citation
Inglis, B., K. Buckenmaier, P. SanGiorgio, A. F. Pedersen, M. A. Nichols, and J. Clarke. “MRI of the Human Brain at 130 Microtesla.” Proceedings of the National Academy of Sciences 110, no. 48 (November 19, 2013): 19194–19201.
Version
Final published version
Abstract
We present in vivo images of the human brain acquired with an ultralow field MRI (ULFMRI) system operating at a magnetic field B[subscript 0] ∼ 130 μT. The system features prepolarization of the proton spins at B[subscript p] ∼ 80 mT and detection of the NMR signals with a superconducting, second-derivative gradiometer inductively coupled to a superconducting quantum interference device (SQUID). We report measurements of the longitudinal relaxation time T[subscript 1] of brain tissue, blood, and scalp fat at B[subscript 0] and B[subscript p], and cerebrospinal fluid at B[subscript 0]. We use these T[subscript 1] values to construct inversion recovery sequences that we combine with Carr–Purcell–Meiboom–Gill echo trains to obtain images in which one species can be nulled and another species emphasized. In particular, we show an image in which only blood is visible. Such techniques greatly enhance the already high intrinsic T[subscript 1] contrast obtainable at ULF. We further present 2D images of T[subscript 1] and the transverse relaxation time T[subscript 2] of the brain and show that, as expected at ULF, they exhibit similar contrast. Applications of brain ULFMRI include integration with systems for magnetoencephalography. More generally, these techniques may be applicable, for example, to the imaging of tumors without the need for a contrast agent and to modalities recently demonstrated with T[subscript 1ρ] contrast imaging (T[subscript 1] in the rotating frame) at fields of 1.5 T and above.
MIT Department
Massachusetts Institute of Technology. Department of Physics
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
https://doi.org/10.1073/pnas.1319334110