Improved magnetic resonance fingerprinting reconstruction with low-rank and subspace modeling: A Subspace Approach to Improved MRF Reconstruction

Thumbnail Image
Download
Name

nihms860285.pdf

Description
Accepted version
Size

1.86 MB

Format

Adobe PDF

Checksum (MD5)

73cda0099f59ffe363d7b6217dfd616e

sword-2019-05-01T16:12:47.original.xml (130 B)
Original SWORD entry document
Author(s)
Zhao, Bo
•
Setsompop, Kawin
•
Adalsteinsson, Elfar
•
Gagoski, Borjan
•
Ye, Huihui
•
Ma, Dan
•
Jiang, Yun
•
Ellen Grant, P
•
Griswold, Mark A
•
Wald, Lawrence L
Date Issued
2018
Journal
Magnetic Resonance in Medicine
Publisher
Wiley
Citation
Zhao, B., et al. "Improved Magnetic Resonance Fingerprinting Reconstruction with Low-Rank and Subspace Modeling." Magn Reson Med (2017).
Version
Author's final manuscript
Abstract
© 2017 International Society for Magnetic Resonance in Medicine Purpose: This article introduces a constrained imaging method based on low-rank and subspace modeling to improve the accuracy and speed of MR fingerprinting (MRF). Theory and Methods: A new model-based imaging method is developed for MRF to reconstruct high-quality time-series images and accurate tissue parameter maps (e.g., T1, T2, and spin density maps). Specifically, the proposed method exploits low-rank approximations of MRF time-series images, and further enforces temporal subspace constraints to capture magnetization dynamics. This allows the time-series image reconstruction problem to be formulated as a simple linear least-squares problem, which enables efficient computation. After image reconstruction, tissue parameter maps are estimated via dictionary-based pattern matching, as in the conventional approach. Results: The effectiveness of the proposed method was evaluated with in vivo experiments. Compared with the conventional MRF reconstruction, the proposed method reconstructs time-series images with significantly reduced aliasing artifacts and noise contamination. Although the conventional approach exhibits some robustness to these corruptions, the improved time-series image reconstruction in turn provides more accurate tissue parameter maps. The improvement is pronounced especially when the acquisition time becomes short. Conclusions: The proposed method significantly improves the accuracy of MRF, and also reduces data acquisition time. Magn Reson Med 79:933–942, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/135755
DOI of Published Version
10.1002/MRM.26701
https://doi.org/10.1002/MRM.26701
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.