Improved magnetic resonance fingerprinting reconstruction with low-rank and subspace modeling: A Subspace Approach to Improved MRF Reconstruction
Name
nihms860285.pdf
Description
Accepted version
Size
1.86 MB
Format
Adobe PDF
Checksum (MD5)
73cda0099f59ffe363d7b6217dfd616e
Author(s) • • • • • • • • •
Zhao, Bo
Setsompop, Kawin
Adalsteinsson, Elfar
Gagoski, Borjan
Ye, Huihui
Ma, Dan
Jiang, Yun
Ellen Grant, P
Griswold, Mark A
Wald, Lawrence L
Date Issued
2018
Journal
Magnetic Resonance in Medicine
Publisher
Wiley
Citation
Zhao, B., et al. "Improved Magnetic Resonance Fingerprinting Reconstruction with Low-Rank and Subspace Modeling." Magn Reson Med (2017).
Version
Author's final manuscript
Abstract
© 2017 International Society for Magnetic Resonance in Medicine Purpose: This article introduces a constrained imaging method based on low-rank and subspace modeling to improve the accuracy and speed of MR fingerprinting (MRF). Theory and Methods: A new model-based imaging method is developed for MRF to reconstruct high-quality time-series images and accurate tissue parameter maps (e.g., T1, T2, and spin density maps). Specifically, the proposed method exploits low-rank approximations of MRF time-series images, and further enforces temporal subspace constraints to capture magnetization dynamics. This allows the time-series image reconstruction problem to be formulated as a simple linear least-squares problem, which enables efficient computation. After image reconstruction, tissue parameter maps are estimated via dictionary-based pattern matching, as in the conventional approach. Results: The effectiveness of the proposed method was evaluated with in vivo experiments. Compared with the conventional MRF reconstruction, the proposed method reconstructs time-series images with significantly reduced aliasing artifacts and noise contamination. Although the conventional approach exhibits some robustness to these corruptions, the improved time-series image reconstruction in turn provides more accurate tissue parameter maps. The improvement is pronounced especially when the acquisition time becomes short. Conclusions: The proposed method significantly improves the accuracy of MRF, and also reduces data acquisition time. Magn Reson Med 79:933–942, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
Persistent DSpace Link
DOI of Published Version
10.1002/MRM.26701
https://doi.org/10.1002/MRM.26701