Nonlinear Behavior of a Shim Coil in an LTS/HTS NMR Magnet With an HTS Insert Comprising Double-Pancake HTS-Tape Coils
Name
Hahn_Nonlinear-Behavior.pdf
Size
204.91 KB
Format
Adobe PDF
Checksum (MD5)
6d2c1f37112c0c2b16511cbfa0d52d2a
Author(s) • • • •
Iwasa, Yukikazu
Bascunan, Juan
Yao, Weijun
Ahn, Min Cheol
Hahn, Seung-Yong
Date Issued
July 2009
Journal
IEEE Transactions on Applied Superconductivity
Publisher
Institute of Electrical and Electronics Engineers
Citation
Seung-yong Hahn et al. “Nonlinear Behavior of a Shim Coil in an LTS/HTS NMR Magnet With an HTS Insert Comprising Double-Pancake HTS-Tape Coils.” Applied Superconductivity, IEEE Transactions on 19.3 (2009): 2285-2288. © 2009 IEEE
Version
Final published version
Abstract
This paper reports results, experimental and analytical, of the nonlinear behavior of a shim coil in the presence of an HTS coil assembled with double-pancake (DP) HTS-tape coils. The experimental results are from: 1) operation of a 700 MHz LTS/HTS NMR magnet (LH700) consisting of a 600 MHz LTS NMR magnet (L600) equipped with superconducting shim coils and a 100 MHz DP-assembled HTS insert (H100) and; 2) an experiment with a room-temperature (RT) Z1 shim coil coupled to a 50 MHz DP-assembled HTS insert (H50). A field mapping theory with a harmonic analysis is applied to interpret both results. Based on experimental results and analyses, we conclude that the screening-current-induced field (SCF) generated by a DP-assembled HTS insert is primarily responsible for the nonlinear behavior, including strength degradation, of a shim coil.
MIT Department
Francis Bitter Magnet Laboratory (Massachusetts Institute of Technology)
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
DOI of Published Version
http://dx.doi.org/10.1109/tasc.2009.2018809