Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Cardiac output and stroke volume estimation using a hybrid of three models

Cardiac output and stroke volume estimation using a hybrid of three models

Thumbnail Image
Download
Name

Arai-2010-Cardiac output and s.pdf

Size

397.37 KB

Format

Adobe PDF

Checksum (MD5)

c37cc41553a0afa652c0f93d2406a6fe

Author(s)
Arai, Tatsuya
•
Lee, Kichang
•
Cohen, Richard J.
Date Issued
August 2010
Journal
Proceedings of the 32nd Annual International Conference of the IEEE, Engineering in Medicine and Biology Society (EMBC 2010)
Publisher
Institute of Electrical and Electronics Engineers
Citation
Arai, T., Kichang Lee, and R.J. Cohen. “Cardiac Output and Stroke Volume Estimation Using a Hybrid of Three Windkessel Models.” Engineering in Medicine and Biology Society (EMBC), 2010 32nd Annual International Conference of the IEEE. Buenos Aires, Argentina, August 31 - September 4, 2010. 4971-4974. © 2011 IEEE.
Version
Final published version
Abstract
Cardiac output (CO) and stroke volume (SV) are the key hemodynamic parameters to be monitored and assessed in ambulatory and critically ill patients. The purpose of this study was to introduce and validate a new algorithm to continuously estimate, within a proportionality constant, CO and SV by means of mathematical analysis of peripheral arterial blood pressure (ABP) waveforms. The algorithm combines three variants of the Windkessel model. Input parameters to the algorithm are the end-diastolic pressure, mean arterial pressures, inter-beat interval, and the time interval from end-diastolic to peak systolic pressure. The SV estimates from the three variants of the Windkessel model were weighted and integrated to provide beat-to-beat SV estimation. In order to validate the new algorithm, the estimated CO and SV were compared to those obtained through surgically implanted Transonic™ aortic flow probes placed around the aortic roots of six Yorkshire swine. Overall, estimation errors in CO and SV derived from radial ABP were 10.1% and 14.5% respectively, and 12.7% and 16.5% from femoral ABP. The new algorithm demonstrated statistically significant improvement in SV estimation compared with previous methods.
MIT Department
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Department of Aeronautics and Astronautics
Terms of Use
Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.
Persistent DSpace Link
http://hdl.handle.net/1721.1/64992
DOI of Published Version
https://doi.org/10.1109/iembs.2010.5627225
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.