Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Enhancing Building Fire Safety Performance by Reducing Miscommunication and Misconceptions

Enhancing Building Fire Safety Performance by Reducing Miscommunication and Misconceptions

Thumbnail Image
Download
Name

10694_2013_Article_365.pdf

Size

900.57 KB

Format

Adobe PDF

Checksum (MD5)

1cd2fad338d4e098cd1cf9a54b7bff09

Download all files submitted through automated deposit
art_912744788086144373.zip (770.65 KB)
Author(s)
Park, Haejun
•
Meacham, Brian J.
•
Dembsey, Nicholas A.
•
Goulthorpe, Mark
Date Issued
November 2013
Journal
Fire Technology
Publisher
Springer US
Citation
Park, Haejun et al. “Enhancing Building Fire Safety Performance by Reducing Miscommunication and Misconceptions.” Fire Technology 50.2 (2014): 183–203.
Version
Author's final manuscript
Abstract
Building fire safety is driven by regulations and technical building codes, at least as a minimum requirement. As fire protection engineers (FPEs) design fire safety measures based on requirements in the regulations, they are often viewed as the primary agents in ensuring the fire safety of buildings. However, their mission often starts with given building design features, such as interior spatial layout, exterior shape, site plan, and so forth, which are mostly determined by architects. The only exception is where the FPE is invited to assist in the project planning, feasibility and early concept design stages of a project. Regardless, architects also can influence building fire safety performance, whether or not they explicitly acknowledge or understand this. Although architects design buildings within the boundaries of the regulatory requirements, the architect’s focus is often related to the visual and spatial aesthetics of buildings linked to building form and functionality, which are not subject to the regulations. These aesthetics can sometimes compete with fire safety objectives. As such, buildings can be unsafe in certain situations due to unintended effects of building design features on actual fire safety performance. This research describes the relationship between architecturally conceived building design features, design expectations for fire safety systems, and the actual or conceivable fire safety performance of the building. Steps are proposed that FPEs can take to identify and address potentially competing objectives and deliver increased fire safety performance.
MIT Department
Massachusetts Institute of Technology. Department of Architecture
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/106034
DOI of Published Version
https://doi.org/10.1007/s10694-013-0365-2
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.