Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. A double exponential chirp waveform for noisy rheology

A double exponential chirp waveform for noisy rheology

Thumbnail Image
Download
Name

397_2025_1514_ReferencePDF.pdf

Size

2.92 MB

Format

Adobe PDF

Checksum (MD5)

dbf36ddf0f0ee931caac41d237211e3d

Download all files submitted through automated deposit
art_6188329657657773061.zip (2.69 MB)
Author(s)
Waeterloos, Jarno L.
•
McKinley, Gareth H.
•
Clasen, Christian
Date Issued
September 23, 2025
Journal
Rheologica Acta
Publisher
Springer Berlin Heidelberg
Citation
Waeterloos, J.L., McKinley, G.H. & Clasen, C. A double exponential chirp waveform for noisy rheology. Rheol Acta 64, 633–646 (2025).
Version
Author's final manuscript
Abstract
In the search for faster rheometrical measurements techniques for fast time-evolving systems, optimally windowed chirps (OWCh) have recently been proposed for the determination of the complex modulus. However, such chirps are prone to artefacts at high frequencies due to fact that the input power is distributed over a range of frequencies leading to reduced signal-to-noise ratios in noisy conditions. The Tukey window which modulates the amplitude of the excitation disturbance and which is required to avoid spectral leakage directly reduces the signal-to-noise ratio at the edges of the signal leading to a divergence of the measured moduli at high frequencies. A new double exponential chirp (DEC) signal is proposed to overcome these limitations. Its capabilities are demonstrated with orthogonal superposition rheometry as an example of a demanding high-noise environment. The S-shaped time-frequency history of the new chirp signal redistributes the input power over the frequency spectrum. Numerical simulations using the Maxwell and Giesekus models, along with orthogonal superposition measurements on wormlike micellar fluids, demonstrate the effectiveness of the DEC waveform. Parameter optimization with the Giesekus model identifies the ideal input configurations for achieving a maximum signal-to-noise ratio during rheological measurements.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-ShareAlike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/163670
DOI of Published Version
https://doi.org/10.1007/s00397-025-01514-x
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.