Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Effects of Low Endothelial Shear Stress After Stent Implantation on Subsequent Neointimal Hyperplasia and Clinical Outcomes in Humans

Effects of Low Endothelial Shear Stress After Stent Implantation on Subsequent Neointimal Hyperplasia and Clinical Outcomes in Humans

Thumbnail Image
Download
Name

Effects of low.pdf

Size

1.12 MB

Format

Adobe PDF

Checksum (MD5)

09870c1d1a4b3eba7cde8ac89717570b

Download all files submitted through automated deposit
sword-2017-12-14.original.zip (965.02 KB)
Author(s)
Shishido, Koki
•
Antoniadis, Antonios P.
•
Takahashi, Saeko
•
Tsuda, Masaya
•
Mizuno, Shingo
•
Andreou, Ioannis
•
Papafaklis, Michail I.
•
Coskun, Ahmet U.
•
Feldman, Charles L.
•
Saito, Shigeru
more
Date Issued
September 2016
Journal
Journal of the American Heart Association
Publisher
Ovid Technologies (Wolters Kluwer Health)
Citation
Shishido, Koki, et al. “Effects of Low Endothelial Shear Stress After Stent Implantation on Subsequent Neointimal Hyperplasia and Clinical Outcomes in Humans.” Journal of the American Heart Association, vol. 5, no. 9, Sept. 2016, p. e002949.
Version
Final published version
Abstract
Background: In-stent hyperplasia (ISH) may develop in regions of low endothelial shear stress (ESS), but the relationship between the magnitude of low ESS, the extent of ISH, and subsequent clinical events has not been investigated. Methods and Results: We assessed the association of poststent ESS with neointimal ISH and clinical outcomes in patients treated with percutaneous coronary interventions (PCI). Three-dimensional coronary reconstruction was performed in 374 post-PCI patients at baseline and 6 to 10 months follow-up as part of the PREDICTION Study. Each vessel was divided into 1.5-mm-long segments, and we calculated the local ESS within each stented segment at baseline. At follow-up, we assessed ISH and the occurrence of a clinically indicated repeat PCI for in-stent restenosis. In 246 total stents (54 overlapping), 100 (40.7%) were bare-metal stents (BMS), 104 (42.3%) sirolimus-eluting stents, and 42 (17.1%) paclitaxel-eluting stents. In BMS, low ESS post-PCI at baseline was independently associated with ISH (β=1.47 mm 2 per 1-Pa decrease; 95% CI, 0.38-2.56; P < 0.01). ISH was minimal in drug-eluting stents. During follow-up, repeat PCI in BMS was performed in 21 stents (8.5%). There was no significant association between post-PCI ESS and in-stent restenosis requiring PCI. Conclusions: Low ESS after BMS implantation is associated with subsequent ISH. ISH is strongly inhibited by drug-eluting stents. Post-PCI ESS is not associated with in-stent restenosis requiring repeat PCI. ESS is an important determinant of ISH in BMS, but ISH of large magnitude to require PCI for in-stent restenosis is likely attributed to factors other than ESS within the stent.
MIT Department
Institute for Medical Engineering and Science
Harvard University--MIT Division of Health Sciences and Technology
Terms of Use
Creative Commons Attribution-NonCommercial 4.0 International
http://creativecommons.org/licenses/by-nc/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/112765
DOI of Published Version
https://doi.org/10.1161/JAHA.115.002949
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.