  4. Using Effective Generator Impedance for Forced Oscillation Source Location

Using Effective Generator Impedance for Forced Oscillation Source Location

Thumbnail Image
Download
Name

1708.01893v2.pdf

Description
Accepted version
Size

1.7 MB

Format

Adobe PDF

Checksum (MD5)

52e4d8606d002f1f17d2f37ea713f0b7

sword-2024-05-29T20:10:34.original.xml (130 B)
Original SWORD entry document
Author(s)
Chevalier, Samuel C.
•
Vorobev, Petr
•
Turitsyn, Konstantin
Date Issued
November 2018
Journal
IEEE Transactions on Power Systems
Publisher
Institute of Electrical and Electronics Engineers
Citation
S. C. Chevalier, P. Vorobev and K. Turitsyn, "Using Effective Generator Impedance for Forced Oscillation Source Location," in IEEE Transactions on Power Systems, vol. 33, no. 6, pp. 6264-6277, Nov. 2018.
Version
Author's final manuscript
Abstract
Locating the sources of forced low-frequency oscillations in power systems is an important problem. A number of proposed methods demonstrate their practical usefulness, but many of them rely on strong modeling assumptions and provide poor performance in certain cases for reasons still not well understood. This paper proposes a systematic method for locating the source of a forced oscillation by considering a generator's response to fluctuations of its terminal voltages and currents. It is shown that a generator can be represented as an effective admittance matrix with respect to low-frequency oscillations, and an explicit form for this matrix, for various generator models, is derived. Furthermore, it is shown that a source generator, in addition to its effective admittance, is characterized by the presence of an effective current source, thus giving a natural qualitative distinction between source and nonsource generators. Detailed descriptions are given of a source detection procedure based on this developed representation, and the method's effectiveness is confirmed by simulations on the recommended testbeds (e.g., WECC 179-bus system). This method is free of strong modeling assumptions and is also shown to be robust in the presence of measurement noise and generator parameter uncertainty.
MIT Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Terms of Use
Creative Commons Attribution-Noncommercial-ShareAlike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/155092
DOI of Published Version
https://doi.org/10.1109/tpwrs.2018.2834229
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.