In-situ measurements of surface tension-driven shape recovery in a metallic glass
Name
Schuh-In situ measurements of surface.pdf
Size
282.43 KB
Format
Adobe PDF
Checksum (MD5)
eb6ce36c46e1b294183ffa226cbc89ca
Author(s) • •
Packard, Corinne E.
Schroers, Jan
Schuh, Christopher A.
Date Issued
March 2009
Journal
Scripta Materialia
Publisher
Elsevier
Citation
Packard, Corinne E., Jan Schroers, and Christopher A. Schuh. “In situ measurements of surface tension-driven shape recovery in a metallic glass.” Scripta Materialia 60.12 (2009): 1145-1148.
Version
Author's final manuscript
Abstract
A new technique, involving nanoindentation and in situ scanning probe microscopy at high temperature under an inert atmosphere, is used to study deformation of a Pt-based metallic glass. As temperature is increased into the supercooled liquid regime, impressions made by nanoindentation flatten due to surface tension-driven viscous flow. In situ measurements of shape recovery at various temperatures and times permit an estimation of the apparent activation energy for Newtonian-viscous flow.