Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Super-resolution 4D flow MRI to quantify aortic regurgitation using computational fluid dynamics and deep learning

Super-resolution 4D flow MRI to quantify aortic regurgitation using computational fluid dynamics and deep learning

Thumbnail Image
Download
Name

10554_2023_Article_2815.pdf

Size

1.74 MB

Format

Adobe PDF

Checksum (MD5)

e1ceaadeb5c3d05aa388ebcb427fb073

Download all files submitted through automated deposit
art_3363809649157048600.zip (1.43 MB)
Author(s)
Long, Derek
•
McMurdo, Cameron
•
Ferdian, Edward
•
Mauger, Charlène A.
•
Marlevi, David
•
Nash, Martyn P.
•
Young, Alistair A.
Date Issued
February 23, 2023
Publisher
Springer Netherlands
Citation
Long, Derek, McMurdo, Cameron, Ferdian, Edward, Mauger, Charlène A., Marlevi, David et al. 2023. "Super-resolution 4D flow MRI to quantify aortic regurgitation using computational fluid dynamics and deep learning."
Version
Final published version
Abstract
Abstract Changes in cardiovascular hemodynamics are closely related to the development of aortic regurgitation (AR), a type of valvular heart disease. Metrics derived from blood flows are used to indicate AR onset and evaluate its severity. These metrics can be non-invasively obtained using four-dimensional (4D) flow magnetic resonance imaging (MRI), where accuracy is primarily dependent on spatial resolution. However, insufficient resolution often results from limitations in 4D flow MRI and complex aortic regurgitation hemodynamics. To address this, computational fluid dynamics simulations were transformed into synthetic 4D flow MRI data and used to train a variety of neural networks. These networks generated super-resolution, full-field phase images with an upsample factor of 4. Results showed decreased velocity error, high structural similarity scores, and improved learning capabilities from previous work. Further validation was performed on two sets of in vivo 4D flow MRI data and demonstrated success in de-noising flow images. This approach presents an opportunity to comprehensively analyse AR hemodynamics in a non-invasive manner.
MIT Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/148224
DOI of Published Version
https://doi.org/10.1007/s10554-023-02815-z
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.