A Review of Corrosion under Insulation: A Critical Issue in the Oil and Gas Industry

Thumbnail Image
Download
Name

metals-12-00561-v2.pdf

Size

2.73 MB

Format

Adobe PDF

Checksum (MD5)

9bbf1035581fa68e774c56a05a44089f

Download all files submitted through automated deposit
packager-6254341d.zip (2.32 MB)
Author(s)
Cao, Qing
•
Pojtanabuntoeng, Thunyaluk
•
Esmaily, Marco
•
Thomas, Sebastian
•
Brameld, Michael
•
Amer, Ayman
•
Birbilis, Nick
Date Issued
March 25, 2022
Publisher
Multidisciplinary Digital Publishing Institute
Citation
Metals 12 (4): 561 (2022)
Version
Final published version
Abstract
Corrosion under insulation (CUI) is defined as any form of external corrosion that occurs on the underlying metal beneath insulated equipment, due to water ingress through the insulation layer. This type of corrosion is frequently observed in oil and gas production, where insulated piping is prevalent, and has historically remained a predominant materials integrity issue. The prediction and direct visualisation of CUI are challenging tasks because of the coverage of the insulation layer(s) and any external jacketing or cladding. Several factors, including the local/ambient environment, system design, and the piping installation process, can influence how CUI initiates and propagates. In this review, CUI background, CUI monitoring, and CUI mitigation strategies are discussed.
Terms of Use
Creative Commons Attribution
https://creativecommons.org/licenses/by/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/141822
DOI of Published Version
http://dx.doi.org/10.3390/met12040561
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.