Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Role of silica nanoparticles in monitoring and prolonging release of drug-eluting polyelectrolyte coatings using long-period fiber grating platform

Role of silica nanoparticles in monitoring and prolonging release of drug-eluting polyelectrolyte coatings using long-period fiber grating platform

Thumbnail Image
Download
Name

Revision manuscript_JoshuaMin.pdf

Description
Accepted version
Size

236.52 KB

Format

Adobe PDF

Checksum (MD5)

c7564bcb37a726db1f456430f1702b86

sword-2020-06-08T17:02:06.original.xml (130 B)
Original SWORD entry document
Author(s)
Tian, Fei
•
Kaňka, Jiří
•
Min, Jouha
•
Hammond, Paula T
•
Yang, Fan,S.M.Massachusetts Institute of Technology.
Date Issued
November 2017
Journal
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Citation
Tian, Fei et al. "Role of silica nanoparticles in monitoring and prolonging release of drug-eluting polyelectrolyte coatings using long-period fiber grating platform." Sensors and Actuators B: Chemical (November 2017): 831-839 © 2017 Elsevier B.V.
Version
Author's final manuscript
Abstract
Silica nanoparticles (SNPs) were synergistically integrated with long-period grating (LPG) platform and the process of layer-by-layer (LbL) assembly to enable monitoring controlled release of drug-eluting polyelectrolyte coatings. The SNPs afforded a high surface area for increased drug loading as well as enhanced evanescent field overlap. In addition, the SNPs positioned within the LbL coatings acted as diffusion barrier layer, leading to prolonged release profile. SNPs with different sizes were respectively immobilized on the LPG using poly allylamine hydrochloride (PAH). In-situ monitoring of drug-eluting LbL coating [chitosan (CHI)/Poly arylic acid (PAA)/Gentamicin sulfate (GS)/PAA]n was carried out on LPG with a sensitivity of 8.1 nm shift/tetralayer for LPG with 1 layer of SNPs with 50 nm in diameter. LPG without the SNPs for the monitoring of [CHI/PAA/GS/PAA]n shows a sensitivity of 2.4 nm shift/tetralayer, indicating the significant ability of SNPs in enhancing the LPG sensitivity. Drug release measurement carried out on the LPG platform revealed an increased release time for LbL-SNP drug delivery system compared with that of LbL alone.
MIT Department
Massachusetts Institute of Technology. Department of Chemical Engineering
Koch Institute for Integrative Cancer Research at MIT
Terms of Use
Creative Commons Attribution-NonCommercial-NoDerivs License
http://creativecommons.org/licenses/by-nc-nd/4.0/
Persistent DSpace Link
https://hdl.handle.net/1721.1/125800
DOI of Published Version
https://doi.org/10.1016/j.snb.2017.06.048
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.