Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Real-time Closed-loop Control in a Rodent Model of Medically Induced Coma Using Burst Suppression

Real-time Closed-loop Control in a Rodent Model of Medically Induced Coma Using Burst Suppression

Thumbnail Image
Download
Name

Brown_Real-time closed-loop.pdf

Size

1.24 MB

Format

Adobe PDF

Checksum (MD5)

2108bde7f99b4fe5eff165ad3ded89bc

Author(s)
Liberman, Max Y.
•
Chemali, Jessica J.
•
Westover, M. Brandon
•
Kenny, Jonathan D.
•
Solt, Ken
•
Purdon, Patrick Lee
•
Ching, Shinung
•
Brown, Emery Neal
Date Issued
October 2013
Journal
Anesthesiology
Publisher
Ovid Technologies (Wolters Kluwer) - Lippincott Williams & Wilkins
Citation
Ching, ShiNung, Max Y. Liberman, Jessica J. Chemali, M. Brandon Westover, Jonathan D. Kenny, Ken Solt, Patrick L. Purdon, and Emery N. Brown. “Real-Time Closed-Loop Control in a Rodent Model of Medically Induced Coma Using Burst Suppression.” Anesthesiology 119, no. 4 (October 2013): 848–860.
Version
Author's final manuscript
Abstract
Background:: A medically induced coma is an anesthetic state of profound brain inactivation created to treat status epilepticus and to provide cerebral protection after traumatic brain injuries. The authors hypothesized that a closed-loop anesthetic delivery system could automatically and precisely control the electroencephalogram state of burst suppression and efficiently maintain a medically induced coma. Methods:: In six rats, the authors implemented a closed-loop anesthetic delivery system for propofol consisting of: a computer-controlled pump infusion, a two-compartment pharmacokinetics model defining propofol’s electroencephalogram effects, the burst-suppression probability algorithm to compute in real time from the electroencephalogram the brain’s burst-suppression state, an online parameter-estimation procedure and a proportional-integral controller. In the control experiment each rat was randomly assigned to one of the six burst-suppression probability target trajectories constructed by permuting the burst-suppression probability levels of 0.4, 0.65, and 0.9 with linear transitions between levels. Results:: In each animal the controller maintained approximately 60 min of tight, real-time control of burst suppression by tracking each burst-suppression probability target level for 15 min and two between-level transitions for 5–10 min. The posterior probability that the closed-loop anesthetic delivery system was reliable across all levels was 0.94 (95% CI, 0.77–1.00; n = 18) and that the system was accurate across all levels was 1.00 (95% CI, 0.84–1.00; n = 18). Conclusion:: The findings of this study establish the feasibility of using a closed-loop anesthetic delivery systems to achieve in real time reliable and accurate control of burst suppression in rodents and suggest a paradigm to precisely control medically induced coma in patients. A closed-loop anesthesia delivery system using a computer-controlled infusion of propofol can achieve a reliable and accurate real-time control of burst suppression in rats.
MIT Department
Massachusetts Institute of Technology. Institute for Medical Engineering & Science
Harvard University--MIT Division of Health Sciences and Technology
Massachusetts Institute of Technology. Department of Brain and Cognitive Sciences
Picower Institute for Learning and Memory
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/102344
DOI of Published Version
https://doi.org/10.1097/ALN.0b013e31829d4ab4
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.