Repository logo
Log in(current)
Repository logoMIT Open ScholarshipDSpace@MIT
  1. Home
  2. MIT Open Access Articles
  3. MIT Open Access Articles
  4. Micrometer-scale magnetic imaging of geological samples using a quantum diamond microscope

Micrometer-scale magnetic imaging of geological samples using a quantum diamond microscope

Thumbnail Image
Download
Name

1707.06714.pdf

Size

3.02 MB

Format

Adobe PDF

Checksum (MD5)

5cc938b94517ed64b65c61daff446be8

Download all files submitted through automated deposit
sword-2018-10-04.original.zip (2.89 MB)
Author(s)
Glenn, D. R.
•
Kehayias, P.
•
Walsworth, R. L.
•
Fu, Roger Rennan
•
Le Sage, David A
•
Lima, E. A.
•
Weiss, Benjamin P.
Date Issued
August 2017
Journal
Geochemistry, Geophysics, Geosystems
Publisher
American Geophysical Union (AGU)
Citation
Glenn, D. R., R. R. Fu, P. Kehayias, D. Le Sage, E. A. Lima, B. P. Weiss, and R. L. Walsworth. “Micrometer-Scale Magnetic Imaging of Geological Samples Using a Quantum Diamond Microscope.” Geochemistry, Geophysics, Geosystems 18, no. 8 (August 2017): 3254–3267.
Version
Author's final manuscript
Abstract
Remanent magnetization in geological samples may record the past intensity and direction of planetary magnetic fields. Traditionally, this magnetization is analyzed through measurements of the net magnetic moment of bulk millimeter to centimeter sized samples. However, geological samples are often mineralogically and texturally heterogeneous at submillimeter scales, with only a fraction of the ferromagnetic grains carrying the remanent magnetization of interest. Therefore, characterizing this magnetization in such cases requires a technique capable of imaging magnetic fields at fine spatial scales and with high sensitivity. To address this challenge, we developed a new instrument, based on nitrogen-vacancy centers in diamond, which enables direct imaging of magnetic fields due to both remanent and induced magnetization, as well as optical imaging, of room-temperature geological samples with spatial resolution approaching the optical diffraction limit. We describe the operating principles of this device, which we call the quantum diamond microscope (QDM), and report its optimized image-area-normalized magnetic field sensitivity (20 µT⋅µm/Hz1/2), spatial resolution (5 µm), and field of view (4 mm), as well as trade-offs between these parameters. We also perform an absolute magnetic field calibration for the device in different modes of operation, including three-axis (vector) and single-axis (projective) magnetic field imaging. Finally, we use the QDM to obtain magnetic images of several terrestrial and meteoritic rock samples, demonstrating its ability to resolve spatially distinct populations of ferromagnetic carriers.
MIT Department
Lincoln Laboratory
Massachusetts Institute of Technology. Department of Earth, Atmospheric, and Planetary Sciences
Terms of Use
Creative Commons Attribution-Noncommercial-Share Alike
http://creativecommons.org/licenses/by-nc-sa/4.0/
Persistent DSpace Link
http://hdl.handle.net/1721.1/118918
DOI of Published Version
https://doi.org/10.1002/2017GC006946
Repository logo
PrivacyPermissionsAccessibilityContact us
Repository logo
Notify us about copyright concerns.